tousek
/ EN_TPS-60-PRO_05 / 25. 03. 2020
- 9 -
The existing limit switches define the final
positions of the gate movement.
Moreover, a mechanical EMERGENCY switch
ensures additional security.
In addition, mechanical stops are indispen-
sable to prevent the gate from moving out
of the guide!
2.5 Dismantling
The dismantling of motor is made the other way around of mounting.
Before dismantling plug off power supply of motor !
2.4 Limit switches and E-Stop Button
Installation
• Additional vertically adjustable reed limit switches and a mechanical emergency shutdown switch (spring bar switch) in
the motor housing ensure a high degree of security in both movement.directions.
• The compulsory magnetic limit switches and emergency stop triggers must be mounted at the required positions on
the rack (horizontal adjustability) and can act as trigger, if necessary.
E
2 x Reed switches (to define the end positions)
N
1 x EMERGENCY switch (spring bar switch):
additional protection of the system in both directions
e
2 x Magnets to trigger the reed limit switches
n
2 x EMERGENCY trigger
to operate the EMERGENCY STOP switch
LEFT
RIGHT
OUTSIDE
e
n
n
LEFT
RIGHT
INSIDE
E
E
N
e
N
E
View from
INSIDE
n
e
n
RIGHT
LEFT
e
E
E
N
View from
OUTSIDE
n
n
e
e