I NSTALLATIO N AND SE TUP
:
1. Select a convenient location in your shop or commercial space to localize charging for your battery power
equipment (120V/ 20A max load demand for each of your items needing charging). For every 8 items to be
charged ensure you have (1) PDM-20 unit and (2) a 15/20R outlet.
2. Connect unit to power, plugging in the NEMA 5-20P/C19 power cord to the input connector (see below)
3. Watch for operational LEDs to light up once 1-8 on the front panel to complete their initiation sequence to
demonstrate operational unit status.
4. Once complete, start plugging in charge units to the output receptacles 1-8 on the reverse face as needed.
5. The software controls within the unit will automatically sweep available loads and determine the optimal
configuration of open/closed outlets to keep total demand under 16A. As units become fully charged the
software will automatically re-balance the configuration of open and closed outlets to keep overall demand
within the limit of the socket powering the unit.
Power Distribution Manager, Back Panel
Receptacle for input
power connection.
Indicated presence of potentially harmful
electrical shock hazards. De-energize circuit and
consult instruction prior to operation.
SAFETY: Board is UL Component certified under
UL File E206903
•
Switching and monitoring, 120-240Vac 50/
60Hz, 30A input
•
120V/16A output per channel
•
NWGQ: Information Technology Equipment
Including Business Equipment
Plug in battery powered equipment for recharge to outlets 1
– 8.
Protected under the following patents and patent pending: 20040064198,20040064198, 7550870, 7630186,7672104
210 Curtner Ave. Unit 6
|
Campbell, CA 95008
|
phone: 650-204-0019
|
info@towatools.com
Remote connectivity & interface available.
Contact us for details