2      TC36.NG01 

080205-8

CONTROL BOX RELOCATION

The gas control system is housed in a control box remote 
of the fi replace. Flexible conduits attach the control box to 
the fi replace and house all the the plumbing and wiring to 
the burner.

The control box is shipped inside the fi rebox and needs to be 
installed. Although the control box may be install on the right 
or left side, the fi replace is assembled at the factory to accept 
the control box from the right hand side. (Fig. # 1)

If installing on the left hand side, the casing and fi rebox inlet 
covers must fi rst be removed and reinstalled on the opposite 
side of the unit. The manifold will also need to be repositioned 
once the burner is installed. This is done by removing two 
retaining screws, turning the manifold over and re-attaching. 
See Fig. #3.

DEFAULT INSTALLATION

1)  Insert the inlet box into the opening at the base of the right 

hand side of the unit as shown in fi g # 1 taking care not 
to damage pilot, plumbing or wires.

2)  Install 4 screws from the inside of the fi rebox to secure 

the inlet box to the fi rebox.

3)  Install Panel Set. (Refer to “Firebox Panels Installation” 

in the Installation and Operating Instruction manual)

INSTALL SCREWS TO SECURE INLET BOX

REPOSITION MANIFOLD

Fig. # 3

Fig. # 1

INSERT CONTROL ASSEMBLY

Fig. # 2

INLET BOX

A panel set must be installed prior to the installation of 
the burner/grate assembly. See Installation and Operating 
Instructions manual for details.

Summary of Contents for TC36.NG01

Page 1: ...5096 981 B HARDWARE PACKAGE PART TC36 NGHDWR These instructions are supplementary to the Installation and Operating Instructions supplied with the fireplace and should be kept together Refer to the Installation and Operating Instructions for proper gas supply safety requirements and operating instructions IMPORTANT THESE INSTRUCTIONS ARE TO REMAIN WITH THE APPLIANCE INSTRUCTIONS ...

Page 2: ...e unit The manifold will also need to be repositioned once the burner is installed This is done by removing two retaining screws turning the manifold over and re attaching See Fig 3 DEFAULT INSTALLATION 1 Insert the inlet box into the opening at the base of the right hand side of the unit as shown in fig 1 taking care not to damage pilot plumbing or wires 2 Install 4 screws from the inside of the ...

Page 3: ...he burner is flush with the front of the shield See fig 4 2 Attach pilot bracket to burner assembly Fig 5 3 Connect flex gas line to the manifold assembly and ensure the connection is gas tight 4 Position the grate in the slots of the burner tray and attach to the floor shield with two screws through holes located behind the front legs of the grate Fig 6 Fig 4 Fig 6 BURNER TRAY INSTALLATION GRATE ...

Page 4: ...desired flame affect Reduce the amount used on Propane models as too much will create soot LOG SET ASSEMBLY The logs are packaged in a foam pack inside the box and are fragile and should be handled with care Unpack and inspect log set There should be a total of 6 logs Gas plumbing and vent connections should be completed before proceeding Position the logs as indicated by the following pictures Pl...

Page 5: ...4 Middle Log Placement Step 5 Bottom Left Log Placement 3 4 5 Fig 9 2 5 3 6 1 4 Fig 11 Fig 10 Note Improper placement of logs may cause sooting on internal parts and glass The logs may need to be reposi tioned slightly to avoid excessive flame impingement ...

Page 6: ...kandstringy The shutter may also be opened to enhance the Ember Material glow and lessen the flame height Caution Burner area may be hot Turn off the fireplace and allow the unit to cool before pro ceeding To Adjust See Fig 12 1 Open and remove window frame and set aside See WindowFrameRemoval sectionfoundintheInstallation and Operating Instructions manual 2 Remove the log set and set aside 3 Loos...

Page 7: ...NER TRAY SUPPORT SHIELD 9789 01 7 BURNER TRAY SHIELD GASKET 9789 5 1 2 6 7 5 3 4 REPLACEMENT PARTS DESCRIPTION PART NO LOG SET COMPLETE 5098 7461 REAR 1 shown in fig 11 5098 741 LEFT 2 shown in fig 11 5098 742 RIGHT 3 shown in fig 11 5098 743 MIDDLE 4 shown in fig 11 5098 744 BOTTOM LEFT 5 shown in fig 11 5098 745 BOTTOM CENTRE 6 shown in fig 11 5098 746 Fig 14 IDENTIFICATION NUMBER ...

Page 8: ...2975 Allenby Rd Duncan BC V9L 6V8 Phone 1 888 223 0088 Web site www townandcountryfireplaces net Printed in Canada ...

Reviews: