2 TC36.NG01
080205-8
CONTROL BOX RELOCATION
The gas control system is housed in a control box remote
of the fi replace. Flexible conduits attach the control box to
the fi replace and house all the the plumbing and wiring to
the burner.
The control box is shipped inside the fi rebox and needs to be
installed. Although the control box may be install on the right
or left side, the fi replace is assembled at the factory to accept
the control box from the right hand side. (Fig. # 1)
If installing on the left hand side, the casing and fi rebox inlet
covers must fi rst be removed and reinstalled on the opposite
side of the unit. The manifold will also need to be repositioned
once the burner is installed. This is done by removing two
retaining screws, turning the manifold over and re-attaching.
See Fig. #3.
DEFAULT INSTALLATION
1) Insert the inlet box into the opening at the base of the right
hand side of the unit as shown in fi g # 1 taking care not
to damage pilot, plumbing or wires.
2) Install 4 screws from the inside of the fi rebox to secure
the inlet box to the fi rebox.
3) Install Panel Set. (Refer to “Firebox Panels Installation”
in the Installation and Operating Instruction manual)
INSTALL SCREWS TO SECURE INLET BOX
REPOSITION MANIFOLD
Fig. # 3
Fig. # 1
INSERT CONTROL ASSEMBLY
Fig. # 2
INLET BOX
A panel set must be installed prior to the installation of
the burner/grate assembly. See Installation and Operating
Instructions manual for details.