TC36_NG04D 240317-24
5056.427D4
Figure 5: Access cover to valve control center.
Figure 6: Flex line bent to shape.
4
3. The base panel (Figure 4) is not used with the Tranquility burner kit and is a left over item to be
discarded.
4. Remove the 10 screws securing the access cover for the valve control center (Figure 5).
5. Bend the larger flexible gas supply line, the smaller flexible pilot gas line along with the ignition
and sensor wires into shape (Figure 6) so that the right hand side cover will fit over top of them
before the burner is placed into the firebox (Figure 8). This cover must be positioned into the
burner before the burner is placed into the firebox as there is no room to install the cover once
the burner is in the firebox.
Figure 4: Base panel.