background image

HOLE

For complete valve installation instructions, refer to the  
instruction book included in the SIT conversion kit.

TC42_NG04D_091014-16

10

5.    With a 7/16” wrench loosen the pilot head 

on the pilot assembly using a wrench to 
hold the bracket steady. (Fig. #19)

6.   Slide the pilot adjustment band over and 

ensure that the hole in the orifice band 
is showing.

Fig. #20a shows NG position

Fig. #20b shows LP position)

Re-attach the pilot assembly.

7.  

  Remove the access panel, 10 screws, 

and set aside.

8.    Remove the minimum rate screw 

located in the valve. (Fig. #21)

The minimum rate screw is sealed with  

 

an o-ring. Use a thin bladed 

 

screwdriver to back the screw out past  

 

the limit of the threading. At this point  

 

a groove on the screw body will be 

 

visible just above the valve body. Insert  

 

a thin tool (knife blade or fine 

 

screwdriver blade) into the groove and  

 

gently pry the screw up.

Fig #19

Fig #20a

Fig #21

NG POSITION

LP POSITION

Fig #20b

Summary of Contents for TC42.NG04D

Page 1: ...tallation and Operating Instructions supplied with the fireplace and should be kept together Refer to the Installation and Operating Instructions for proper gas supply safety requirements and operating instructions TC42 TRANQUILITY BURNER KIT INSTALLATION INSTRUCTIONS PART TC42 NG04D For TC42 Series D Fireplaces 091014 16 TC42_NG04D 5056 426D4 ...

Page 2: ...e not required to attach this style of burner 1 Bend flex lines into the approximate shape Fig 1 2 Place covers under the burner tray Fig 2 3 NOTE Shutter must be fully closed for Natural gas fully open for Propane Contents of Package 1 BURNER ASSEMBLY 1 PANEL BASE 1 PEBBLE ASSEMBLY 1 COVER RHS 1 COVER LHS 3 4 LBS SAND 1 BAG TAPERED PLUGS Tranquility Burner Installation Fig 1 Fig 2 Fig 3 ...

Page 3: ...assembly into the firebox against the rear panel Fig 4 Place panel clips under both rear corners of the base plate as shown in Fig 4a approx 3 from rear panel 4 Attach the manifold supply tube and the pilot supply tube to the bulk head fittings and tighten Fig 5 Ensure that there are no leaks Fig 4 Fig 5 Fig 4a ...

Page 4: ...KHEAD PLATE 2 SCREWS Fig 6 Fig 7 5 Secure the electrical bulkhead plate Fig 6 and gasket to the firebox 2 screws Attach the ignition and sensor wires to the module Fig 7 INTERFACE MODULE IGNITION WIRE RED FLAME SENSOR WIRE WHITE ...

Page 5: ... Remove panel retainer from upper heat shield Install right porcelain panel tilting in from front corner Fig 8 Slip the side panels into the panel clip as shown in Fig 9 Finish the installation as per instructions Fig 8 Fig 9 ...

Page 6: ...panel and behind the right panel While supporting the upper rear panel install and secure left porcelain panel in the same manner as the right panel Fig 10 8 Securewiththepreviouslyremovedpanel retainer 9 Slide covers out and attach to base with one screw each Fig 11 Fig 10 Fig 11 ...

Page 7: ...s into raised burner portstopreventsandfromenteringports Fig 12 11 Place sand in tray Brush sand smooth andleveltojustbelowtopofraisedburner ports Fig 13 12 Gently blow excess sand from around ports 13 Remove tapered plugs from ports Fig 12 Fig 13 ...

Page 8: ...ocks on top of the pebble assembly Sooting will occur Fig 14 Fig 15 14 Remove pebble assembly from packaging by placing hand on top and tipping upside down Gently place pebble assembly onto sand base using pins to locate position Fig 14 15 Placetrimrocksatdesiredlocationsinthe sandaroundthepebbleassembly Install glass door Unit is ready for lighting ...

Page 9: ...CAUTION The gas supply and electrical power shall be shut off before proceeding with the conversion Note Factory supplied components must be used to ensure correct input After conversion confirm proper manifold pressure 1 Removethe2frontscrewsholdingthe burner tray in place Fig 16 2 Gently lift up the burner tray while sliding to the left to disengage the burner tube from the orifice Then tip back...

Page 10: ...shows NG position Fig 20b shows LP position Re attach the pilot assembly 7 Remove the access panel 10 screws and set aside 8 Remove the minimum rate screw located in the valve Fig 21 The minimum rate screw is sealed with an o ring Use a thin bladed screwdriver to back the screw out past the limit of the threading At this point a groove on the screw body will be visible just above the valve body In...

Page 11: ...fireplace has reached operating temperature See Fig 22 for proper flame pattern Open primary air if the window glass and firebox have carbon accumulation and or the flames are long dark and stringy The shutter may also be opened to lessen the flame height NOTE Proper air shutter setting is required For Propane the primary shutter must be fully open The flame should be just orange and lazy It shoul...

Page 12: ...lacement Parts 1 BURNER ASSEMBLY 1a TRANQUILITY CURB 1b 19 PORT CAST BURNER 1c ROCK PAN 1d LINE COVER LT 1e TRANQUILITY LEG 1f FLOOR PAN 1g TAPPED 1 8 27 NPT 1h LINE COVER RT 1i BURNER INLET TUBE 1j CURB CLAMP 2 PEBBLE ASSEMBLY 3 MAIN SUPPLY TUBE 4 PILOT TUBE 5 PILOT ASSEMBLY CONVERTIBLE 6 ORIFICE NG 25 TAPERED PLUGS not shown 7 PROPANE CONVERSION KIT not shown 8 SAND not shown 2 PEBBLE ASSEMBLY 3...

Page 13: ...13 TC42_NG04D_091014 16 ...

Page 14: ...TC42_NG04D_091014 16 14 ...

Page 15: ...15 TC42_NG04D_091014 16 ...

Page 16: ...w townandcountryfireplaces net 2975 Allenby Rd Duncan BC V9L 6V8 Printed in Canada 2014 Copyright Pacific Energy Fireplace Products LTD Reproduction adaptation or translation without prior written permission is prohibited except as allowed under the copyright laws ...

Reviews: