Figure 33: TC42D Wall vent terminal framing.
Vent pipe:
Install vent pipe through the wall thimble and attach to flue outlet collar on top of the fireplace. Secure all joints with screws
and seal with approved "High Temp." self-adhesive aluminum tape provided.
Adjust the fireplace position so that the vent pipe does not protrude beyond the outer wall. The vent connector on the
termination will accomodate walls up to 12" thick.
Wall vent terminal:
1. Engage the terminal with the vent pipe and slide terminal into place. Ensure that both inner and outer pipes are fully
engaged and then attach the terminal to the outside wall. The vent terminal must not be recessed into the exterior
wall or siding.
2. Caulk in place to prevent any moisture entering the building.
NOTE: MINIMUM CLEARANCES TO THE VENT TERMINAL MUST BE MAINTAINED. See page 25.
HORIZONTAL
TERMINAL
TCVT.9360
14 1/2" FRAMED
OPENING
WALL SHIELD THIMBLE
TCVT.THIMA
ELBOW
TCVT.811XLB90
24"
VENT PIPE
TCVT.811X24
12" VENT PIPE
TCVT.811X12
* MINIMUM HEIGHT FROM THE FLOOR
TO CENTER OF THE OPENING WITH
A MAXIMUM HORIZONTAL RUN OF
18" FROM THE CENTER OF THE FLUE
OUTLET TO THE OUTSIDE FACE OF
THE OUTER WALL. THE HEIGHT WILL
NEED TO BE INCREASED IF A LONGER
HORIZONTAL PIPE IS REQUIRED.
*
74 1/4"