10. Slip the gas burner venturi over the orifice and screw the burner leg to the secondary floor panel using a
T20 screw (Figure 9).
11. Place the second burner in the firebox so that its venturi fits over the second orifice. Secure the leg to the
secondary floor panel.
Figure 9: Securing the burner leg to the secondary floor panel.
3/16” Open for Propane Gas
Fully closed for Natural Gas
Figure 10: Shutter gap settings.
TCWS.54NGST03D_210417-24
5056.425181D
NOTE: Check air shutter for correct fuel setting before proceeding further. Both burner shutters
are to be set the same. Fully closed for NATURAL GAS and 3/16” open for LIQUID PROPANE.
CAUTION: The burners should be tightly butted up against each other at the center to ensure
correct operation.
8