background image

5056.425217-A

Remote Flame Control

The Profl ame2 has six (6) fl ame levels. With the fi replace turned on, and 
the fl ame level at maximum height, press the down arrow key once to 
reduce the fl ame height by one step (Figure 9) until the fl ame is turned 
off. 

The up arrow key will increase the fl ame height each time it is pressed. If 
the up arrow key is pressed while the fi replace is on but the fl ame is off, 
the fl ame will come on in the high position. A single “beep” will confi rm 
reception of the command.

Room Thermostat (Transmitter Operation)

The remote control transmitter can operate as a room thermostat. The thermostat can be set to a desired 
temperature to control the comfort level in a room. To activate this function, press the thermostat key 
(Figure 1). The LCD display on the remote control transmitter will change to show that the room thermostat is 
“ON” and the set temperature is now displayed (Figure 10). To adjust the set point, press the up or down 
arrow keys until the desired set point temperature is displayed on the LCD screen of the remote control 
transmitter.

Smart Thermostat (Transmitter Operation)

The Smart Thermostat function adjusts the fl ame height in accordance to the difference between the set point 
and the room temperatures. As the room temperature gets closer to the set point, the Smart Function will 
modulate the fl ame down. If the room temperature is cool, the Smart Function will modulate the fl ame up. To 
activate this function, press the THERMOSTAT button (Figure 1) until the word “SMART” appears to the right of 
the temperature icon (Figure 11). To adjust the set point, press the up or down arrow buttons until the desired 
set point temperature is displayed on the LCD screen of the remote control transmitter.

The thermostat key (Figure 1) on the remote handset needs to be held down. Keep it pressed down and 
remove one of the three batteries from the remote handset. Simply re-install the battery that was removed 
and the feature is activated. Use the same procedure to disable the thermostat function.

 Instructions  for enabling the Thermostat function for Canadian users.

Flame Off

Flame level 5

Flame level Max

Flame level 1

Figure 9:   Flame level control.

Figure 10:   Room temperature  
 control.

Figure 11:   Smart fl ame   
 control.

Figure 12:  Smart fl ame 
function set low.

9

TCWS54DST_

160517-16

Summary of Contents for TCWS54D

Page 1: ...flammable vapors and liquids in the vicinity of this or any other appliance This appliance may be installed in an aftermarket permanently located manufactured home USA only or mobile home where not prohibited by local codes This appliance is only for use with the type of gas indicated on the rating plate This appliance is not convertible for use with other gases unless a certified kit is used This...

Page 2: ... 5 Fireplace Description 7 Transmitter Remote Control with LCD Display 7 IFC Module 7 Operating Procedure 7 Using the Remote Control Transmitter 8 Temperature indication Display 8 Turn on the Fireplace 8 Turn off the Fireplace 8 Manual Bypass of the Remote Fireplace 8 Remote Flame Control 9 Room Thermostat Transmitter Operation 9 Smart Thermostat Transmitter Operation 9 Instructions for enabling t...

Page 3: ...ition which is the result either directly or indirectly of any improper operation or installation procedures This appliance must not be connected to a chimney flue serving a separate solid fuel burning appliance FOR YOUR SAFETY Do not install or operate your Town Country fireplace without first reading and understanding this manual Any installation or operational deviation from the following instr...

Page 4: ...the fireplace to OFF turn off all electric power to the fireplace and call your service technician or gas supplier Note Sufficient time must be allowed for air to escape from lines if the unit is being lit for the first time 4 Push the On Off switch to the fireplace Off 5 Allow sufficient length of time minimum 5 minutes for any gas in the combustion chamber to escape If you still smell gas STOP F...

Page 5: ...use discomfort to some individuals It is normal for fireplaces fabricated of steel to give off some expansion and or contraction noises during the start up or cool down cycle Similar noises are found with your furnace heat exchanger or cook stove oven Remote Control Operation NOTE Fireplace may take up to 30 seconds to ignite each time the ON button has been selected Special Operator Note Blue bac...

Page 6: ...the fireplace power supply circuit breaker OFF ON SMART MAX MAX KEY LOCK LOW BATTERY ALARM ROOM TEMPERATURE CPI MODE DIMMER ON FLAME LEVEL SET POINT TEMPERATURE LEVEL STATE THERMOSTAT OFF ON SMART TRANSMISSION SEE NOTICE REGARDING THERMOSTAT USE SEE NOTICE REGARDING THERMOSTAT USE SEE NOTICE REGARDING Figure 2 Proflame 2 LCD screen details NOTICE The thermostat function is disabled by default Ther...

Page 7: ...ration giving the choice of both IPI intermittent pilot ignition and CPI continuous pilot ignition modes The Proflame2 IFC module controls and connects directly to the pilot assembly and the automatic valve using low electric power The IFC module can be powered by both an AC power supply and battery pack for back up The Proflame 2 offers the added ability to control the comfort fan speed from OFF ...

Page 8: ... module will confirm reception of the command Figure 3 Wall switch interface side Program button Turn off the Fireplace With the fireplace ON press the ON OFF key on the remote control transmitter The remote control transmit ter LCD display will only show the room temperature Figure 7 and Figure 8 At the same time the IFC module will turn off the fireplace A single beep from the IFC module confirm...

Page 9: ...ontrol transmitter Smart Thermostat Transmitter Operation The Smart Thermostat function adjusts the flame height in accordance to the difference between the set point and the room temperatures As the room temperature gets closer to the set point the Smart Function will modulate the flame down If the room temperature is cool the Smart Function will modulate the flame up To activate this function pr...

Page 10: ...when a key is pressed Key Lock This function will lock the keys to avoid unsupervised operation To activate this func tion press the MODE and UP keys at the same time Figure 1 The lock icon will appear Figure 15 To de activate this function press the MODE and UP key at the same time Remote dimmer control Light The auxiliary function controls the AUX power outlet by the dimmable light control To ac...

Page 11: ...ch Step 1 Procedure for linking pairing wall switch to fireplace 1 Set the wall switch selector to the Remote setting 2 Press and hold Program button Figure 17 on the wall switch for up to 10 seconds Use a straight ened paper clip to access the button 3 The wall switch will beep 5 times Release the button following the beeps 4 The fireplace will beep 3 times repeated by another 3 beeps 5 The firep...

Page 12: ...o activate the fireplace Step 3 Optional procedure for linking pairing a Blue Tooth enabled apple mobile device to the fireplace iOS only 1 Download the TC Fire app from the Apple App Store 2 From your device open the app and go to Add Edit Fireplace 3 Press the Add button Find the PIN number located on a sticker on the wall switch Figure 20 4 Enter the PIN number and a user defined description of...

Page 13: ...le buttons Figure 24 turn the functions ON and OFF while the sliders increase and decrease the flame and lighting lev els Figure 19 Home screen Figure 20 Wall switch with PIN number Figure 21 Add edit progam fields Figure 22 PIN name entry Figure 23 App programed for living room Figure 24 Control sliders 13 TCWS54DST_160517 16 ...

Page 14: ...et faces the fireplace Re install glass retaining clips Annual Inspection a Remove glass panel and pebble assemblies Inspect pebble and burner assemblies for soot buildup If excessive buildup of soot is present have a qualified service person inspect and adjust unit for proper combustion Clean logs and burner with a brush or vacuum cleaner paying close attention to burner ports b Check the pilot s...

Page 15: ...5056 425217 A 15 TCWS54DST_160517 16 ...

Page 16: ...tion adaptation or translation without prior written permission is prohibited except as allowed under the copyright law For technical support please contact your retailer Web site www townandcountryfireplaces com 2975 Allenby Rd Duncan BC V9L 6V8 Printed in Canada ...