5056.4252155D
MINIMUM VENT HEIGHT
Various combinations of vent runs
may be used. Refer to Figure 36
for details. For optimum perfor-
mance and flame appearance,
keep the vent length to a minimum
and limit the number of elbows.
Connections between each vent
system component must be tightly
joined, secured with sheet metal
screws and sealed.
CAUTION:
Under no condition
should combustible
material be closer than
1 3/4 inches from any
part of the vent pipe.
Only 45º elbows can be
used in this vent system.
Maximum number of
elbows is 2.
Roof Termination Venting Chart
This fireplace can be roof terminated using either the TCVT. PVCV power vent kit or the TCVT.RTA direct vent kit. Please
see the instructions supplied with the kit forinstallation details.
20'
10'
8'
6
40'
MAX.
4'
2'
48'
4' MAX.
'
18” MIN BEFORE ELBOW
Figure 36: Roof venting chart.
22
TCWS54_D 150817-40