5056.4252155D
D
12”
E
6 3/4”
F
1 1/2”
MANTEL CLEARANCE
CHART
* MANTEL CLEARANCE
** MANTEL DEPTH
A
9”
B
6”
C
3”
MAY USE COMBUSTIBLE
FACING MATERIAL IN THIS AREA
NON-COMBUSTIBLE
FINISH MATERIAL
SEE FIG #11 & 13
NON-COMBUSTIBLE ZONE.
DO NOT INSTALL ANY COMBUSTIBLE MATERIAL,
ELECTRICAL WIRING OR GAS PLUMBING IN THIS
AREA.
COMBUSTIBLE FRAMING AND
FINISH WALL ABOVE STANDOFFS
STANDOFFS
STEEL FRAMING
FIREPLACE FRONT
TOP OF LINTEL BAR
A
B
C
D
E
F
Figure 2: TCWS54D Mantel clearances.
29 3/4"
24"
4“
CEILING
ADJACENT WALL
OR MANTEL SUPPORT
12”
COMBUSTIBLE FL
OOR
COMBUSTIBLE HEARTH
*
**
Figure 3: TCWS54D Minimum mantel clearances.
Minimum Clearances:
Side standoffs ...................................................... 0 in.
(0 mm)
Back standoff ....................................................... 0 in.
(0 mm)
Top standoffs ........................................................ 0 in.
(0 mm)
Bottom of appliance ............................................. 0 in.
(0 mm)
Adjacent side wall ................................................ 4 in.
(102 mm)
Ceiling to appliance ............................................ 24 in.
(610 mm)
*Mantel to appliance ..............................See Figure #2
**Maximum Mantel extension ................See Figure #2
Mantel support ..................................................... 4 in.
(102 mm)
Vertical vent pipe .......................................... 1 3/4" in.
(45 mm)
5
TCWS54_D 021216-40
Fireplace Dimensions
Minimum Clearances to Combustible Material
71 15/16"
55"
11 1/2"
18 5/8"
5 5/8"
35 3/4"
23 1/2"
25 5/16"
71 15/16"
54 7/16"
13 3/4"
Figure 1: TCWS54 Dimensions.