Locate the fi replace as per the main instructions supplied.
Make the following modifi cations to add the components used with the Flush
Mount Power Vent Kits. This Kit can only be used in conjunction with the “C” series
versions of Town and Country fi replaces, except the TC54.CE. This installation must
conform with local codes or, in the absence of local codes, with the National Fuel
Gas Code, ANSI Z223.1/NFPA 54, or the Natural Gas and Propane Installation Code,
CSA B149.1.
All electrical installations should be performed by a qualifi ed electrician to the
Canadian and U.S. National Electrical Codes (CSA C22.1 for Canada), (ANSI/NFPA
70 for the U.S.) and/or local electrical codes.
UNDER NO CIRCUMSTANCES SHALL A RHEOSTAT BE USED
TO ALTER THE VOLTAGE SUPPLY TO THIS UNIT.
ITEM PART
No.
DESCRIPTION
QTY
1
TCVT.8018
Flush Mount Power Vent Assy.
1
2
8020
Inner wall plate
1
3
8029
Wall Pipe cover
1
4 TCVT.8028WLD
Wall
Sleeve
Assembly
1
MINIMUM CLEARANCES TO
COMBUSTIBLE
Terminal casing:
0in.
(0mm)
Vertical vent pipe:
1.75 in. (38mm)
Horizontal vent pipe:
1.75 in. (38mm)
All other clearances are as per the fi replace
installation instructions.
VENTING CONFIGURATIONS
Maximum total vent length
is 110ft plus six 90-degree
elbows or combination of other
elbows equaling 90-degrees,
with a maximum 66 foot
vertical rise.
Minimum total vent length is
one 90-degree elbow plus one
foot horizontal.
The vent can be installed with
any combination of rise and
run including up to 3 ft below
the unit. Ensure vent pipe is
properly supported.
Maximum Combined
vertical & horizontal
venting -
110 ft plus six
90-degree elbows.
Min. venting - one
90-degree elbow plus
one foot horizontal.
3 ft. below unit (Max) to
center of vent pipe
66’ MAX. VERTICAL
Min. 1 3/4” Clearance to
combustible surfaces from
vent pipe.
PAINT:
The vent terminal comes pre-painted
with Thurmalox 230 Series paint by
Dampney Co., but can be painted
to match your wall fi nish color
using high temperature paint that
can withstand temperatures of at
least 250 degrees Fahrenheit or 120
degrees Celcius.
Ensure the your paint is compatible
with Thurmalox 230 Series paint.
Fig. #26
Venting Confi gurations
TCVT.PVOFM Power Vent Installation
Contents of Power Vent Kit
20
TCWS.54CSTE 110712-72
Summary of Contents for TCWS54ST SERIES D