mbr-36 mbr-42
13
Town Food Service Equipment Company, Inc.
718/388-5650 outside New York State 800/221-5032
TrouBlE SHooTING
PIloT BurNEr WIll NoT STaY lIT
This could be caused by one (or more) of three problems:
• Loose connection of the thermocouple lead to the safety control.
• Burned out thermocouple.
• Broken safety control.
To remedy the problem, first check to see that the thermocouple lead is properly tightened in to the safety control head.
1) Check all safeties (figure 1).
2) using a
3
/
8
” wrench, ensure the thermocouple lead is properly tightened in to the body of the saftey control,
a ¼ turn after finger tight will ensure a proper connection (figure 1).
overtightening will damage the control.
Check that the lead tip is not corroded, clean it if necessary with emory cloth.
3) Light the pilot burner. If the pilot burner stays lit, then the problem was a loose connection at the thermocouple.
THE THErmoCouPlE lEaD IS TIGHT BuT THE PIloT BurNEr WIll NoT STaY lIT
Thermocouples require replacement as often as three months due to the extremely high temperatures in the
combustion chamber of the Mongolian barbecue range. To change a themocouple, wait for the unit to cool. Then:
1) using a
3
⁄
8
” wrench, remove the thermocouple from the control (figure 2).
2) using a
7
⁄
16
” wrench, remove the old thermocouple from the pilot assembly. Replace with a new thermocouple by
threading the collar into the safety pilot burner assembly. Install the thermocouple in to the pilot burner. When install-
ing a new thermocouple in the pilot be sure to thread the adjusting collar up to the top of it’s travel (figure 2).
3) After the thremocouple is installed at the pilot burner, thread the brass fitting in to the safety body. It should be snug-
a
1
⁄
4
“ turn after fighter tight is reccommended.
overtightening will damage the control.
Light pilot.
figure 2
figure 4
figure 1
figure 3