mbr-36 mbr-42
16
Town Food Service Equipment Company, Inc.
718/388-5650 outside New York State 800/221-5032
INSTallING a NEW THErmoCouPlE
1) Check that the proper gas orifice is installed in the pilot. The pilot ships with a natural gas orifice installed, a propane
orifice is also supplied. Be sure the orifice is tight before installing the thermocouple. The
“
L
”
pilot, orifice and thremo-
couple are pictured in figure 1.
2) hand tighten nut so thermocouple is snug to top stop. The top stop and threaded lock nut are pictured in figure 2.
3) After the termocouple is installed, insert the pilot tubing into the orifice compression fitting. Push the tube end up as far
as possible. Tighten the compression fitting with a wrench. The pilot tubing and ¼” compression fitting are pictured in
figure 3.
4) Tighten compression fitting until top crimp snaps off; then tighten an additional ¼ turn (figure 4) If everything has been
installed correctly, pilot flame should resemble figure 5.
figure 5
ThERMoCouPLE
1
/
4
”
PILoT TuBING
1
/
4
”
CoMPRESSIoN FITTING
1
/
4
”
CoMPRESSIoN
FITTING
oRIFICE
oRIFICE
figure 1
figure 2
figure 3
figure 4
“
L
”
PILoT
ToP SToP
FLuSh To ToP
ThREADED
LoCkNuT