3) If your unit is supplied with casters, the installation should be made with a gas connector that complies with
the standard for connectors for movable gas appliances, ANSI Z21.69 or connectors for moveable gas
appliances, CAN/CGA-6.16, and a quick disconnect device that complies with the standard for quick
disconnect devices for use with gas fuel ANSI Z21.41, or quick disconnect devices for use with gas fuel,
CAN1-6.9. Adequate means must be provided to limit the movement of the appliance without depending
on connector and the quick disconnect device or it
’
s associated piping to limit movement.
4) If your unit is provided with casters on legs, the legs with locking casters must be installed opposite the gas
supply line. An approved restraining device must be secured to unit near gas supply.
5) Connect the gas line and check for leaks. Air will be trapped in the gas supply lines.
Trapped air can be bled out by pushing the red button in on the pilot safety valve (figure 1) for a few
minutes during initial lighting.
6) With the main valve on and the 3 burner valves
off
(figure A), check for leaks using soapy water or an
electronic leak detector.
do not use open flame for testing.
INITIal lIGHTING aND SHuT DoWN INSTruCTIoNS
Always follow lighting and shutdown instructions below when operating unit. A 5 minute complete shut-off period is
required before lighting or relighting.
1) With burner valves
off
light a match and place in a lighter rod, or use a LP torch (figure 2 and 3). Position the flame
at one pilot burner in the combustion chamber (figure 3). Push the red safety button to turn on gas flow (figure 1).
Place match or torch beneath burner to be ignited (figure2). It may take up to 10 minutes to bleed air trapped in the
gas line before the pilot will light. For detailed instructions on use and repair of the safety pilot system by the manu-
facturer, Inveysis/
R
obertshaw
refer to pages 17-19.
CoNTINuED oN PaGE 5
figure a
BuRNER VALVES IN
off
PoSITIoN—
RoTATE CouNTER CLoCkWISE To TuRN
oN
figure B
BuRNER VALVE IN
oN
PoSITIoN—
RoTATE CLoCkWISE To TuRN
off
red safety
button
figure 3