background image

YW2012 

 

 

Definitions 
 

 

Code Length:

 Length of Master Code defines the length of all other codes. Length of codes can be 4, 5, or 6 digits. Master 

Code and User Codes must be the same length. 

 

LED Indicator:

 LED indicators are located at the top outside of the lock. Lock flashes both green and red LED dependent on 

user inputs. 

 

Master Code:

 Code used to program and unlock the lock. Factory Default Setting Master Code is 12345 - this must be 

changed before programming the lock. Multiple locks can have same Master Code.  

 

Manager Code

: A single lock can have a maximum of 5 Manager Codes. Manager Codes can program User Codes under the 

same group. Manager Codes can be programmed using function 51, 52, 53, 54, and 55.  

 

User ID:

 Two-digit Identification numbers for User Codes. Each User Code must have a User ID (00-99).  

 

User Code:

 Codes used to unlock the lock. User Codes are programmed by the Master or Manager Code. Lock can have a 

maximum of 100 User Codes. Function 02 programs User IDs and their User Codes. 

 

Service Code (One-time User Code):

 Code that allows one-time entry per code. Service Code is automatically deleted after 

it has been used. Lock can have a maximum of 5 Service Codes simultaneously active.  

 

Passage Mode:

 Mode that keeps the lock unlocked until it is disabled. Factory Default Setting has this mode disabled. 

Function 40 enables Passage Mode and Function 41 disables Passage Mode 

 

Pass Time:

 Period that a lock stays in unlocked position after a valid code is entered. Factory Default Setting Pass Time is 5 

seconds. Function 42 adjusts Pass Time from 2 to 20 seconds.  

 

Sound:

 Keypad sound is enabled by Default Factory Setting. Disabling the sound affects general operation and programming 

of the lock. Function 73 disables sound and Function 71 enables Sound.  

 

Lock Status Indicator:

 LED indicator on lock to show whether it is locked (flashing red LED) or unlocked (flashing green 

LED). Function 91 enables or disables the lock status indicator.  

 

Penalty Time (Keypad Anti-Tamper Lockout Time):

 Period that a lock stays in locked position after it reaches its max 

number of incorrect code entries. During Penalty Time, no other codes will be accepted. Factory Default Settings’ Penalty 
Time is 60 seconds after 3 invalid tries. Function 92 adjusts Penalty Time from 0 (disabled) to 90 seconds after 0 (disabled) to 
9 tries. This is used to prevent unauthorized entry.  

 

Remote Access Terminal: 

For remote control button connection. If connected, pushing a remote button will unlock the lock 

for 5 seconds.

 

 

Group Function

A group is defined by the first and last location of User ID’s programmed into a Manager Code. Manager 

Code programs User Codes under the same group. Group Function may be enabled or disabled by Master Code. Manager 
Code may program all User Codes if Group Function is disabled. 

 

Summary of Contents for e-Elite 3000

Page 1: ...YW2012 XCE and XME 2000 Series Locks ...

Page 2: ...e Code Delete Codes 6 Delete User Code Delete Manager Code Delete All Manager Codes Delete Service Code Delete All Service Codes Disable Codes 7 Disable all Codes 7 Passage Mode 8 Pass Time 8 Group Function 8 Sound Settings 9 Lock Status Indicator 9 Penalty Time 10 Code Location Function 10 Next Free User ID 11 Reset Lock to Factory Default Settings 11 Low Battery Warning 11 ...

Page 3: ...as this mode disabled Function 40 enables Passage Mode and Function 41 disables Passage Mode Pass Time Period that a lock stays in unlocked position after a valid code is entered Factory Default Setting Pass Time is 5 seconds Function 42 adjusts Pass Time from 2 to 20 seconds Sound Keypad sound is enabled by Default Factory Setting Disabling the sound affects general operation and programming of t...

Page 4: ...or indicates success and the red LED indicator indicates failure o One green LED flash and 2 short beeps occurs after each program sequence o Two green LED flashes and 2 beeps one short beep and one long beep occur at the end of each successful program sequence o One red LED flash and 1 long beep indicates failure during program sequence The red LED will flash 0 5 second with one long beep after a...

Page 5: ...Key Sequence Master Code Enter 2 Digit Manager ID New Manager Code First 2 Digit User ID Location Last 2 Digit Last Location For example to add Manager code 8888 with Manager ID 51 which manages User ID s 01 10 Press 5555 51 8888 01 10 Up to 5 Manager Codes can be programmed Use 2 digit Manager Code ID s 51 52 53 54 or 55 The 2 Digit First Location and 2 Digit Last Location sets the group of User ...

Page 6: ...respectively Press 5555 02 10 2020 11 2030 12 2040 Input of additional User Codes must start before the green LED indicator stops flashing 8 Seconds otherwise start process from the beginning Add a Service Code Key Sequence Master Code or Manager Code Enter Service Code ID Enter Service Code For example to add Service Code 1 9999 Press 5555 21 9999 Up to 5 Service Codes can be programmed Use Servi...

Page 7: ...des have their own corresponding Delete Code 61 51 65 55 Delete All Manager Codes Key Sequence Master Code 60 60 For example to delete all Manager Codes Press 5555 60 60 Delete a Service Code Key Sequence Master Code or Manager Code Enter Service Delete Code ID For example to delete Service Code 1 Press 5555 31 Up to 5 Service Delete Code ID s 31 32 33 34 or 35 All Service Codes have a correspondi...

Page 8: ... Master Code or Manager Code 06 For example to disable all Users Codes Press 5555 06 All User Codes are disabled and Service Codes are deleted If using Manager Code all User Codes under that Manager Group are disabled Using Manager Code does not delete disable Service Codes Enable all User Codes Key Sequence Master Code or Manager Code 08 For example to enable all User Codes Press 5555 08 All User...

Page 9: ... Code 42 2 digit XX seconds Pass Time changes to XX seconds and XX is programmable from 02 seconds to 20 seconds Enable Group Function Factory Default Key Sequence Master Code 43 For example to Enable Manager Groups Press 5555 43 Managers are restricted to controlling only the User Codes under their set Location Group Disable Group Function Key Sequence Master Code 44 For example to Disable Manage...

Page 10: ...tor Enable Lock Status Indicator Status Locked Red LED Key Sequence Master Code 91 2 Red LED flashes when door is locked Enable Lock Status Indicator Status Unlocked Green LED Key Sequence Master Code 91 3 Green Led flashes when door is unlocked or in Passage Mode Disable Lock Status Indicator No Flashing LED indicator Key Sequence Master Code 91 1 ...

Page 11: ...Key Sequence Master Code or Manager Code 09 Enter Code to be located For example to find the location of code 2010 Press 5555 09 2010 Keypad will light up 2 Digit Code Location If the code entered is recognized the following sequence will occur At the start of the Code Location Function the lock will flash both the green and red LED and emit 2 beeps The keypad will light the 2 digit User ID one di...

Page 12: ...ter Code 99 99 Reset to Factor Default Settings without a Master Code 1 Remove one battery 2 Press and hold the 0 button then replace the battery 3 Release the 0 button after green LED flashes twice and lock beeps twice 4 Within 3 seconds press the star key 3 times The green LED will light for 7 seconds and 2 beeps will sound The lock is reset to the Factory Default Settings All programming is del...

Page 13: ...YW2012 12 ...

Reviews: