background image

 

XCE9000

 

PROGRAMMING

 

AND

 

USER

 

MANUAL

 

 

1

 

 

XCE9000

 

Software

 

Specifications

 

XCE9000

 

is

 

a

 

multidimensional

 

electronic

 

keypad

 

lock,

 

in

 

addition

 

to

 

the

 

keypad

 

there

 

is

 

the

 

remote

 

control

 

emergency

 

device

 

for

 

emergency

 

action

 

(lock

 

down

 

mode).

 

This

 

will

 

immediately

 

lock

 

down

 

all

 

doors

 

associated

 

with

 

the

 

remote

 

control.

 

Passwords

 

and

 

authorizations:

 

 

Master

 

Code:

 

The

 

highest

 

level

 

password,

 

you

 

can

 

set

 

all

 

the

 

lock

 

functions.

 

Master

 

Code

 

can

 

only

 

be

 

changed,

 

cannot

 

be

 

deleted.

 

Factory

 

Master

 

Code

 

is

 

1,

 

2,

 

3,

 

4,

 

5.

  

You

 

must

 

change

 

the

 

password

 

before

 

you

 

use,

 

lock

 

will

 

not

 

program

 

without

 

changing

 

the

 

Master

 

Code.

 

Password

 

length

 

can

 

be

 

4

 

to

 

6

 

digits,

 

all

 

passwords

 

are

 

the

 

same

 

code

 

length

 

as

 

the

 

Master

 

Code.

  

Once

 

you

 

change

 

the

 

code

 

length

 

of

 

the

 

Master

 

Code,

 

all

 

previously

 

entered

 

passwords

 

will

 

be

 

cleared.

 

 

Service

 

Code:

 

Password

 

address

 

is

 

01

 

to

 

10,

 

and

 

reusable.

 

After

 

entering

 

the

 

User

 

Code

 

the

 

door

 

will

 

be

 

relock

 

in

 

5

 

seconds

 

after

 

opening.

 

Note:

 

Address

 

refers

 

to

 

a

 

location

 

in

 

the

 

lock

 

memory

‐ 

if

 

the

 

code

 

is

 

programmed

 

using

 

an

 

address

 

from

 

01

 

to

 

10

‐ 

the

 

lock

 

knows

 

it

 

is

 

a

 

Service

 

Code

 

for

 

example.

 

 

Office

 

Code:

 

Password

 

address

 

is

 

11

 

to

 

90,

 

and

 

reusable.

 

Entering

 

the

 

Office

 

Code

 

will

 

unlock

 

the

 

door

 

and

 

keep

 

the

 

door

 

open.

 

Entering

 

the

 

Office

 

Code

 

again

 

will

 

lock

 

the

 

door

 

and

 

keep

 

the

 

door

 

locked.

 

 

Emergency

 

Code:

 

Password

 

address

 

is

 

91

 

to

 

99,

 

and

 

reusable.

 

The

 

Emergency

 

Code

 

is

 

used

 

to

 

override

 

the

 

lock

 

down

 

mode

 

initiated

 

by

 

triggering

 

the

 

remote

 

control

 

emergency

 

device,

 

you

 

must

 

enter

 

the

 

Emergency

 

Code

 

to

 

release

 

the

 

door

 

and

 

stop

 

the

 

LED

 

flashes.

 

 

Each

 

user's

 

password

 

is

 

unique

 

and

 

different.

 

Using

 

the

 

same

 

password

 

will

 

be

 

rejected.

 

 

Password

 

addresses

 

are

 

01

 

to

 

99

 

for

 

the

 

Service

 

Codes,

 

Office

 

Codes

 

and

 

Emergency

 

Codes.

 

The

 

password

 

addresses

 

determines

 

the

 

type

 

of

 

password.

 

 

Except

 

for

 

the

 

Master

 

Code,

 

all

 

password

 

addresses

 

are

 

empty

 

when

 

shipped

 

from

 

the

 

factory

 

or

 

if

 

the

 

lock

 

is

 

reset.

 

Remote

 

control

 

emergency

 

device

 

and

 

emergency

 

lock

 

status:

 

 

The

 

purpose

 

of

 

the

 

remote

 

control

 

is

 

for

 

locking

 

the

 

door

 

down

 

(lock

 

down

 

mode)

 

in

 

emergencies

 

only.

 

The

 

remote

 

control

 

does

 

not

 

release

 

the

 

lock

 

down

 

mode;

 

it

 

only

 

initiates

 

the

 

lock

 

down

 

mode.

 

 

The

 

effective

 

range

 

for

 

remote

 

control

 

is

 

75

 

feet

 

inside

 

and

 

25

 

feet

 

outside.

 

 

When

 

the

 

door

 

is

 

in

 

lock

 

down

 

mode

 

the

 

red

 

warning

 

LED

 

will

 

flash

 

3

 

times

 

per

 

second.

   

 

In

 

the

 

lock

 

down

 

mode

 

you

 

can

 

still

 

enter

 

Master

 

Code,

 

User

 

Code,

 

and

 

Office

 

Code

 

to

 

unlock

 

the

 

door,

 

but

 

it

 

does

 

not

 

release

 

the

 

lock

 

down

 

mode.

  

 

Entering

 

the

 

Emergency

 

code

 

will

 

deactivate

 

the

 

lock

 

down

 

mode

 

and

 

stop

 

the

 

LED

 

flashing.

 

Summary of Contents for XCE9000 series

Page 1: ...de will unlock the door and keep the door open Entering the Office Code again will lock the door and keep the door locked Emergency Code Password address is 91 to 99 and reusable The Emergency Code is used to override the lock down mode initiated by triggering the remote control emergency device you must enter the Emergency Code to release the door and stop the LED flashes Each user s password is ...

Page 2: ...ter the Office Code on the keypad to unlock XCE9000 remains door open condition until re enter the Office code for locked condition After Enter the Office code on the keypad to unlock Enter Master code or User code in the open condition the door will be locked in 5 seconds Setup XCE9000 functions in the door locked condition Sequentially enter Master code function code etc After successful input t...

Page 3: ...immediately The XCE 900 will only operate a maximum of 200 cycles in low battery If the battery has not been replaced after 200 additional cycles then the lock will only allow Master code to operate the lock The red LED will flash 10 times before opening the door the battery must be changed Reset to factory default XCE9000 can use two different methods to reset to factory default values After rese...

Page 4: ...emote control inner code in the emergency condition 99 Reverting to Factory Setting Programming of the Lock Two blue LED flashes and 2 beeps one short beep and one long beep at the end of a successful program sequence One blue LED flash and 2 short beeps during program sequence Note No other programming commands will be accepted until the Factory Master Code has been changed Program 01 Change Mast...

Page 5: ... from 01 to 10 3 Office Codes are located at locations from 11 to 90 4 Emergency Codes are located at locations from 91 to 99 Program 03 Deleting User Office Emergency Codes Master 0 3 2 digit Location For example delete an Office Code located in location 41 Press 12345 03 41 Note Obviously the locations should be documented this should have the same controls as when issuing keys Program 04 Disabl...

Page 6: ...s recognized the following sequence will occur 1 At the start of the Code Location sequence the lock will flash both the Blue and Red LEDs and emit 2 beeps 2 The lock will identify the first digit by flashing the Blue LED and beeping from 0 9 times 3 To signify the end of the first digit sequence the lock will flash both the Blue and Red LEDs and will emit 2 beeps 4 The lock will identify the seco...

Page 7: ... remote control cover change DIP Switch to 11110000 3 Reinstate the remote control press the emergency button to test that the settings are correct Note XCE9000 and the remote control factory settings are 00000000 Program 99 Reverting to Factory Setting Master Code 9 9 9 9 7 seconds Result The lock memory will be cleared and made to revert to the factory setting Note The Blue LED will light contin...

Page 8: ...an experienced radio TV technician for help FCC Caution To assure continued compliance any changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate this equipment Example use only shielded interface cables when connecting to computer or peripheral devices This device complies with Part 15 of the FCC Rules Operation is subjec...

Reviews: