A

 

“beep”

 

will

 

sound

 

for

 

each

 

press

 

of

 

the

 

keypad

 

keys

 

 

Blue

 

LED

 

indicates

 

acceptance

 

of

 

user

 

input

 

 

Red

 

LED

 

indicates

 

that

 

there

 

is

 

an

 

input

 

error

  

 

Entering

 

the

 

wrong

 

password,

 

the

 

red

 

LED

 

will

 

light

 

for

 

a

 

½

 

second

 

and

 

the

 

buzzer

 

will

 

sound

 

a

 

long

 

beep.

 

 

Setting

 

XCE9000

 

features:

 

such

 

as

 

setting

 

a

 

new

 

Office

 

Code

‐ 

the

 

blue

 

LED

 

flashes

 

twice,

 

buzzer

 

will

 

“beep”

 

twice

 

to

 

indicate

 

acceptance

 

of

 

the

 

settings.

 

Power

 

 

XCE9000

 

uses

 

four

 

alkaline

 

AA

 

batteries

 

as

 

the

 

power

 

source

 

 

Remote

 

Control

 

uses

 

a

 

12V

 

alkaline

 

battery

 

as

 

the

 

power

 

source

 

 

When

 

the

 

battery

 

of

 

XCE9000

 

is

 

low,

 

after

 

entering

 

the

 

correct

 

password,

 

the

 

red

 

light

 

flashes

 

five

 

times

 

before

 

it

 

opens

‐ 

at

 

this

 

point:

  

Change

 

the

 

batteries

 

immediately.

 

 

When

 

the

 

remote

 

control

 

battery

 

is

 

low,

 

after

 

pressing

 

the

 

remote

 

control

 

button,

 

the

 

remote

 

control

 

will

 

still

 

work,

 

but

 

the

 

red

 

light

 

will

 

flash

 

5

 

times

 

to

 

indicate

 

low

 

battery.

 

Change

 

the

 

battery

 

immediately.

 

 

The

 

XCE

 

900

 

will

 

only

 

operate

 

a

 

maximum

 

of

 

200

 

cycles

 

in

 

low

 

battery.

 

If

 

the

 

battery

 

has

 

not

 

been

 

replaced

 

after

 

200

 

additional

 

cycles

 

then

 

the

 

lock

 

will

 

only

 

allow

 

Master

 

code

 

to

 

operate

 

the

 

lock.

 

The

 

red

 

LED

 

will

 

flash

 

10

 

times

 

before

 

opening

 

the

 

door,

 

the

 

battery

 

must

 

be

 

changed.

 

Reset

 

to

 

factory

 

default

 

 

XCE9000

 

can

 

use

 

two

 

different

 

methods

 

to

 

reset

 

to

 

factory

 

default

 

values.

 

After

 

resetting

 

all

 

settings

 

will

 

be

 

cleared,

 

including

 

all

 

passwords,

 

and

 

the

  

Master

 

Code

 

is

 

restored

 

to

 

1,2,3,4,5

 

 

One

 

method

 

is

 

to

 

enter

 

#

 

Master

 

Code

 

 

99

 

 

99

 

 

.

 

The

 

blue

 

LED

 

will

 

lights

 

for

 

7

 

seconds,

 

Buzzer

 

beeps

 

twice

 

to

 

restore

 

factory

 

default

 

settings.

 

(Note:

 

 

indicates

 

blue

 

LED

 

flash)

 

 

Another

 

method:

 

1.

 

Remove

 

one

 

battery

 

from

 

the

 

battery

 

pack.

 

2.

 

Press

 

and

 

hold

 

the

 

"0"

 

button,

 

then

 

replace

 

the

 

battery,

 

the

 

blue

 

LED

 

flashes

 

2

 

times,

 

Buzzer

 

beeps

 

twice,

 

then

 

release

 

"0"

 

button

 

3.

 

Within

 

3

 

seconds,

 

press

 

the

 

"*"

 

button

 

three

 

times,

 

followed

 

by

 

blue

 

LED

 

lights

 

7

 

seconds,

 

Buzzer

 

beeps

 

twice

 

to

 

restore

 

factory

 

default

 

settings.

 

 

If

 

the

 

blue

 

LED

 

doesn’t

 

light

 

for

 

7

 

seconds

 

or

 

the

 

buzzer

 

doesn’t

 

beep

 

twice

 

then

 

the

 

reset

 

failed

 

and

 

you

 

need

 

to

 

repeat

 

the

 

steps.

  

 

 

 

Summary of Contents for XCE9000 series

Page 1: ...de will unlock the door and keep the door open Entering the Office Code again will lock the door and keep the door locked Emergency Code Password address is 91 to 99 and reusable The Emergency Code is used to override the lock down mode initiated by triggering the remote control emergency device you must enter the Emergency Code to release the door and stop the LED flashes Each user s password is ...

Page 2: ...ter the Office Code on the keypad to unlock XCE9000 remains door open condition until re enter the Office code for locked condition After Enter the Office code on the keypad to unlock Enter Master code or User code in the open condition the door will be locked in 5 seconds Setup XCE9000 functions in the door locked condition Sequentially enter Master code function code etc After successful input t...

Page 3: ...immediately The XCE 900 will only operate a maximum of 200 cycles in low battery If the battery has not been replaced after 200 additional cycles then the lock will only allow Master code to operate the lock The red LED will flash 10 times before opening the door the battery must be changed Reset to factory default XCE9000 can use two different methods to reset to factory default values After rese...

Page 4: ...emote control inner code in the emergency condition 99 Reverting to Factory Setting Programming of the Lock Two blue LED flashes and 2 beeps one short beep and one long beep at the end of a successful program sequence One blue LED flash and 2 short beeps during program sequence Note No other programming commands will be accepted until the Factory Master Code has been changed Program 01 Change Mast...

Page 5: ... from 01 to 10 3 Office Codes are located at locations from 11 to 90 4 Emergency Codes are located at locations from 91 to 99 Program 03 Deleting User Office Emergency Codes Master 0 3 2 digit Location For example delete an Office Code located in location 41 Press 12345 03 41 Note Obviously the locations should be documented this should have the same controls as when issuing keys Program 04 Disabl...

Page 6: ...s recognized the following sequence will occur 1 At the start of the Code Location sequence the lock will flash both the Blue and Red LEDs and emit 2 beeps 2 The lock will identify the first digit by flashing the Blue LED and beeping from 0 9 times 3 To signify the end of the first digit sequence the lock will flash both the Blue and Red LEDs and will emit 2 beeps 4 The lock will identify the seco...

Page 7: ... remote control cover change DIP Switch to 11110000 3 Reinstate the remote control press the emergency button to test that the settings are correct Note XCE9000 and the remote control factory settings are 00000000 Program 99 Reverting to Factory Setting Master Code 9 9 9 9 7 seconds Result The lock memory will be cleared and made to revert to the factory setting Note The Blue LED will light contin...

Page 8: ...an experienced radio TV technician for help FCC Caution To assure continued compliance any changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate this equipment Example use only shielded interface cables when connecting to computer or peripheral devices This device complies with Part 15 of the FCC Rules Operation is subjec...

Reviews: