Installation
40
TOX_Manual_FinePress_PFS-PFL-PFW_en
1
4
3
BN
BK
BU
1
4
3
Fig. 2
Allocation of TDC sensor: (BMF 21K-PS-C-2-S49)
1.
Install the holding bracket on the press head.
2.
Position the TDC sensor with holding angle on the tension rod by shift-
ing until a signal is appears on the measuring instrument.
3.
Install the TDC sensor with holding angle on the tension rod.
4.
Set the distance from the TDC sensor via the set screw. The TDC sen-
sor must bear against the pneumatic cylinder.
5.
Connect the cable and install the straight plug in the mounting clip.