Maintenance
TOX_Manual_FinePress_PFS-PFL-PFW_en
57
10.3.2
Inspecting the fastening of the press head
1
1
Fastening screws
ü
System is in maintenance position.
See
Set system to maintenance position, Page 55
.
1.
Check the tightening torque of the fastening screws.
2.
NOTE!
Damage on the tool! Check the alignment of the tool!
Press type
Screw size
Tightening torque
PFS 002.002
M 12
45 Nm
PFL / PFW 004.002
M 12
90 Nm
PFL / PFW 008.002
PFL / PFW 013.002
M 12
135 Nm
all
M 16
340 Nm
all
M 20
720 Nm
Tab. 2
Fastening screws of the press head on the frame