23
13.
COMMON FAULT ANALYSIS
The environmental requirements of the generator:
Suitable temperature: -10
℃
-40
℃
.
Suitable humidity: lower than 95%.
Suitable altitude: under 1,000 meters (it should be used with lower power in districts higher
than 1,000 meters).
The generator set can only be loaded to the rated power under the specified environment
conditions. If the environment conditions are inconsistent with the above standards, or if
the cooling conditions of the engine and generator set are defective; for example, when
Fault
phenomenon
Fault
cause
Operation
method
The
generator
can
not
start
No diesel fuel
Fill the fuel tank with fuel
The fuel switch is not
turned on
Turn the fuel switch to ON
The fuel switch is blocked
Clean the fuel switch
No engine oil or the engine
oil level is low
Add oil
The
speed
control
is turned off
Turn the
speed
control
to
the "RUN" position
Starter
m ot or
does
not
operate
or
rotat es
too
slowly
Clean
terminals
,retight en
Check
batt ery
,
recharge
No
power
output
The circuit breaker is
not connected
Turn the circuit breaker to
the "on" position
The plug is poorly
contacted
Replace a socket
Vibration
while
operation
No diesel fuel
Fill the fuel tank with fuel
The
generator
emits
white
smoke
The temperature of the
engine is too low
Let the engine run at empty
load for m ore than 10 minutes
The fuel oil is contaminated
Replace clean oil
The
generator
emits
black
smoke
The air filter is dirty
Clean the filter element
of the air filter
The load is too high
Reduce load to the
rated limit
The
generator
emits
blue
smoke
The engine oil is too much
Drain some oil
The engine oil type
is incorrect
Choose appropriate engine
oil type(
refer
to
page
16)
The
power
decreases
Fuel
syst em
clogged
Purge
of
or
replace
fuel
vitta
,
filter
or
cock
)
Clogged
air
cleaner
elem ent
Clean
or
replace
filt er
elem ent
Summary of Contents for XP LINE