9. Economic mode in Cooling Mode
1) When it is in economic mode in cooling mode, the set temperature will rise 2
℃
automatically.
2) When it is in economic mode in cooling mode, the indoor fan will work in low flow mode.
10. Super wattage function in Cooling Mode
1) When it is in super wattage mode, the compressor and outdoor fan motor are on all the time, the indoor fan motor
will work in high flow mode.
2) When it is in super wattage mode, the super wattage indicator is on, 15 minutes later, this function will be cancelled
automatically and the indicator will be off.
3) The function fulfils preventing indoor coil frost and outdoor unit working unnormally.
4) Super wattage function can be set under TIMER mode, if it is the set time, the function starts automatically, and 15
minutes later will be cancelled automatically.
二
二
二
二
. Dehumidifying mode
1. Set temperature: 18 – 30
℃
℃
℃
℃
2. First usage of dehumidifying mode, the indoor fan motor will works in low flow
mode for 20 seconds, and begin to work relative to the room temperature.
Four working period: (Ta = room temp. Ts = set temp.)
A : Ta
>
>
>
>
Ts + 3
℃
℃
℃
℃
B : Ts + 3
℃
℃
℃
℃
≥
Ta
>
>
>
>
Ts
C : Ts
≥
Ta
>
>
>
>
Ts - 2
℃
℃
℃
℃
D : Ts - 2
℃
℃
℃
℃
≥
Ta
1. Begin to operate
Compressor ON
A. B Period
Outdoor fan motor OFF
Indoor fan motor ON
Set fan speed OFF
0 12 Minutes
Begin Detecting the temp, Decide the working period
At the first 12 minutes, the working mode is the same as the cooling mode, the compressor stops when the Ta = Ts –
1, when the room temperature rises to Ts, the compressor restarts.
1) When
Ta
>
Ts (A. B period), the unit works in cooling mode for 12 minutes, decide working period with the Ta.
2) If the Ta
≤
Ts (C. D period), the compressor and the indoor fan motor works in low flow mode for 3 minutes, and then
the compressor stops for 3 minutes, indoor fan motor stop after 30 seconds. Repeat the above procedure and go into