52
Only if the compressor and indoor fan run, this function works and all following conditions meet:
a T
coil
<
36
℃;
b Ta
<
18
℃;
c Ta
≤
Ts
-
3
℃
.
This function will shut down if any of following conditions occur:
a
The compressor shut down
;
b T
coil
>
39
℃;
c Ta
≥
20
℃;
d Ta
>
Ts
-
1
℃。
When this function shut down, indoor fan will stop working after 15 seconds delay.
4. Cooling mode
The fan works as set fan speed, the compressor works as set temperature, when Ta is higher than Ts, the compressor
runs, when Ta
≤
Ts – 1
℃
, the compressor will stop, but indoor fan still works, in cooling mode, fan speed can be
choose in high flow, middle flow, and low flow modes. This lead to strong cooling, middle cooling and weak cooling.
Cooling
Cooling
Ts
The compressor stops
Ts
-
1
℃
The compressor stops
5. Dehumidifying mode
a
.
When in dehumidifying mode, the air conditioner will be in cooling mode until Ta = Ts, and then
change into soft dehumidifying mode.
b
.
When into soft dehumidifying mode, the compressor and indoor fan will work for 10 minutes,
during the compressor working period, the fan speed always in low flow.
c
.
When in soft dehumidifying, if Ta
≥
Ts +1
℃
, the air conditioner will change into cooling mode.
Standard cooling mode
Ts
+
1
℃
Standard cooling mode
Ts
soft dehumidifying
soft dehumidifying
Soft dehumidifying, the compressor and the indoor fan work together.
Te
m
p
. D
o
w
n
Te
m
p
. U
p