65
Horn joint
Gas &
liqiud
separator
Compressor
Horn joint
Indoor
heat
exchanger
Outdoor
heat
exchanger
4-way valve
Percolator
Percolator
Refrigerant flow direction
in heating
Defrost
thermistor
Connecting pipe
adiabatic socket
Connecting pipe
adiabatic socket
Capillary 2
Capillary 1
Stop
valve
Indoor-temp
thermistor
Indoor coil
thermistor
Stop valve
(service
mouth)
Refrigerant flow direction
in cooling
二
二
二
二
. Cooling & heat
Pipeline Specifications
:
:
:
:
Model
Gas connecting
pipe outer diameter
(mm)
Liquid connecting pipe
outer diameter (mm)
Capillary 1 Dimension
(mm
×
mm)
Capillary 2 Dimension
(mm
×
mm)
9000 BTU
cooling & heating
9.52 6.35
Φ
1.37
×
850
Φ
1.37
×
350
12000 BTU
cooling & heating
12.7 6.35
Φ
1.62
×
900
Φ
1.62
×
350
18000 BUT
cooling & heating
12.7 6.35
Φ
1.80
×
750
Φ
1.80
×
400
Indoor unit