P14894
Terminal C
Terminal 50
P14895
P14896
P14897
Ammeter
Terminal 30
Battery
ST03X--01
ST--14
--
STARTING
STARTER
TEST
NOTICE:
These tests must be done within 3 to 5 seconds to avoid
burning out the coil.
1. DO PULL -- IN TEST
(a)
Disconnect the field coil lead wire from terminal C.
(b)
Connect the battery to the magnetic switch as shown.
Check that the clutch pinion gear moves outward.
2 . DO HO LD -- I N TE S T
With battery connected as above with the clutch pinion gear
out, disconnect the negative (--) lead from terminal C. Check
that the pinion gear remains out.
3. INSPECT CLUTCH PINION GEAR RETURN
Disconnect the negative (--) lead from the switch body.Check
that the clutch pinion gear returns inward.
4 . DO NO -- LO AD P E RFO RMANCE TE S T
(a)
Connect the battery and ammeter to the starter as shown.
(b)
Check that the starter rotates smoothly and steadily with
the pinion gear moving out. Check that the ammeter
shows the specified current.
Specified current:
1.0 kW, 1.2kW, 1.4kW type:
At 11.5 V: 90 A or less
2.0 kW type:
At 11.5 V: 100 A or less