S04381
+B
Ohmmeter
HT
FI01W--01
--
ELECTRONIC FUEL INJECTION
OXYGEN SENSOR (2RZ--FE)
FI--59
OXYGEN SENSOR (2RZ--FE)
INSPECTION
INSPECT HEATER RESISTANCE OF HEATED OXYGEN
SENSORS
Using an ohmmeter, measure the resistance between terminals
+B and HT. Using an ohmmeter, measure the resistance be-
tween terB and HT.
Resistance:
At 20
˚
C (68
˚
F): 11.7 -- 14.3 k
Ω
If resistance is not as specified, replace the heated oxygen sen-
sor.