7-143
7 DISPLAY
7.2.7.2 SPEED SETTING OF SPEED LIMITER "SPEED LIMIT SET"
GENERAL
The speed limit of the Maximum speed limiter can be changed.
Operating Procedure
Step 1
Enter the password on the general screen to display
the service function "MASK MENU" screen.
Switch (1)
Switch (2)
Switch (4)
Switch (3)
Step 2
Press switch (1) 5 times to check that "6. SPEED
LIMIT SET" is selected, and press (enter) switch (4)
to display the "SPEED LIMIT SET" screen.
Step 3
Change the speed limit to desired value with switch
(2) and switch (3), and press (enter) switch (4) to set
the value and return to service function "MASK
MENU" screen.
▪
"SPEED LIMIT SET"
Switch (2): Setting speed limit down
Switch (3): Setting speed limit up
Switch (4): Entering speed limit and returning to service
function "MASK MENU" screen.
NOTICE:
▪
This function is same as speed setting of speed limiter
of administrator function.
▪
Travel speed level limiter setting function is disabled
with setting level 8.
7
Summary of Contents for 62-8FDU15
Page 5: ...1 3 1 GENERAL 1 2 FRAME NUMBER Frame No Punching Position Punching position 1...
Page 8: ...2 6 2 STEERING 4YM and 1DZ engine W synchronized steering B B A A B B C C C C...
Page 11: ...2 9 2 STEERING 2 3 COMPONENTS 1ZS and 4YE engine 4507 4YM and 1DZ II engine 4507 2...
Page 13: ...2 11 2 STEERING 4YM and 1DZ II engine W synchronized steering 4503 2...
Page 23: ...3 21 3 MATERIAL HANDLING SYSTEM 3 2 COMPONENTS 6801 3...
Page 46: ...5 44 5 OIL CONTROL VALVE 5 2 3 COMPONENTS 1ZS and 4YE engine ASSY FITTING 6705...
Page 55: ...6 53 6 SAS OPS 6...
Page 56: ...6 54 6 SAS OPS Load Sensor 1DZ II engine 5803...
Page 157: ...8 155 8 TROUBLESHOOTING 8 3 WHEN NO ERROR CODE IS DISPLAYED Defect causes related to SAS OPS 8...
Page 191: ...8 189 8 TROUBLESHOOTING 8 4 WHEN ERROR CODE IS DISPLAYED 8...
Page 221: ...Published by 1st Printing Mar 2016 Pub No CE118 Printed in USA...
Page 222: ...PRINTED IN USA Pub No CE118...