4-14. X motor
[Removal]
(1) Remove two setting screws (a) and
motor cover. (Fig.1).
(2) Loosen the nut and remove the
setting screw (b). (Fig.2)
(3) Disconnect the connectors. Remove
two setting screws (c) and the X
motor. (Fig.2)
(4) Remove four setting screws (d) and X
motor from the bracket. (Fig.2)
[Installation]
Power circuit board
Lower shat joint
(1) Mount the X motor to the motor base
with four setting screws (d) (Fig.2).
Sewing machine
motor
(c)
(2) Set the X motor gear to the belt and
temporarily secure the motor base to
the X base B with two setting screws
(c) (Fig.2).
Arm bed
(3) Adjust the belt tension by setting
screw (b) and firmly tighten two
setting screws (c), then tighten the
nut. (Figs.2, 3)
Power circuit board
Note: Check the tension, after tighting
screws (c).
(4) Insert the connector.
(d)
Sewing machine
motor
4.REPLACEMENT OF MAIN COMPONENTS
(a)
Motor cover
-52-
Summary of Contents for ESP9000
Page 1: ...SERVICE MANUAL Embroidery Machine ESP9000 15 needles...
Page 2: ......
Page 13: ...FIG 3 48...
Page 24: ...FIG 4 59...
Page 36: ...Connection of connector CN 10 Must be connected correctly Replace See P 47 CN10 11...
Page 40: ...Picker height C 7 9 mm when piker solenoid is ON Adjust See P 27 15...
Page 58: ...FIG 2 FIG 3 201 3 0 1 0 3 mm 22...
Page 63: ...FIG 4 e Drive arm FIG 5 27...
Page 70: ...FIG 3 34...
Page 72: ...FIG 2 FIG 3 201 3 0 1 0 3 mm 22...
Page 74: ...FIG 2 FIG 3 Needle bar Stopper Needle bar Connecting stud 24...
Page 77: ...FIG 4 e Drive arm FIG 5 27...
Page 84: ...FIG 3 34...
Page 86: ...FIG 4 31...
Page 88: ...FIG 4 33...
Page 90: ...FIG 2 35...
Page 93: ...2 a Sensor arm 3 38...
Page 95: ...FIG 3 FIG 4 VR6 Power supply board 40...
Page 97: ...FIG 3 FIG 4 0 5 to 0 8mm 0 2mm or less Hook support hook support 37...
Page 100: ...FIG 4 40...
Page 103: ...FIG 2 Needle bar c Top dead center stopper needle bar connecting stud FIG 3 43...
Page 105: ...FIG 5 45...
Page 111: ...Printed in Japan 2002 8...