background image

4

The FF 55T is designed for use with Paraffin. Use of low-quality fuel will cause burner performance to drop, leading 

to abnormal combustion and reduced heater life.

Purchase only Paraffin, in non-red cans reserved exclusively for fuel and marked accordingly with the word 

“PARAFFIN”. Always store your fuel in a separate area from where you store gasoline for your power equipment to 

avoid accidental use of gasoline in your heater.

What to Buy . . .

ALWAYS:

Clean and high-quality Paraffin.

ALWAYS:

Fuel free of contaminants, water or cloudiness.

NEVER:

Gasoline, alcohol, white gas, camp stove fuel or additives.

NEVER:

Yellow or sour-smelling fuel.

How to Store It . . .

ALWAYS:

Store in a clean container, clearly marked PARAFFIN.

ALWAYS:

Store away from direct sunlight, heat sources or extreme temperature 

changes.

NEVER:

In a glass container, or one that has been used for other fuels.

NEVER:

For longer than six months. Begin each heating season with 

fresh fuel; discard at the end of season.

NEVER:

In the living space.

Why It is Important . . .

Pure, clean fuel is essential for safe and efficient heater operation. Poor quality or 

contaminated fuel can cause:

 Excess tar deposits on burner and flue pipe

 Incomplete combustion

 Reduced heater life

Use of a highly volatile flammable fuel such as gasoline can produce uncontrolla-

ble flames, creating a severe fire hazard.

SECTION C:
FUEL GUIDE

FF_55T_Type B_US.qxd  14.5.29 15:58  ページ 4

Summary of Contents for FF-55T

Page 1: ...Long Term Storage 18 Section I Installation Standard Installation Parts 19 Optional Accessory Parts 20 Installation Advice 24 Installation of Heater and Flue Pipe 25 Extension Wire of Room Temperatur...

Page 2: ...Fuel Type Paraffin only Dimensions W H D 496 600 339 mm Weight 20 kg Vent Pipe Hole 70 80 mm diameter Maximum Length of Vent Pipe System 3 m 3 bents or less Electrical Rating 220 Volts AC 50 Hz Prehe...

Page 3: ...lure and other conditions Please see page 14 for more details Fully Vented System Flue pipe system provides outside air for combustion and vents all combustion products to the outdoors 1 2 3 4 SAFETY...

Page 4: ...apabilities or lack of experiance and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved Children shall not...

Page 5: ...s NEVER Yellow or sour smelling fuel How to Store It ALWAYS Store in a clean container clearly marked PARAFFIN ALWAYS Store away from direct sunlight heat sources or extreme temperature changes NEVER...

Page 6: ...utton 1 ON OFF switch 8 ON lamp 13 BURNING MODE indicator 14 F C indicator Before using heater familiarize yourself with the following operating controls and part names Outlet opening Inlet opening Ci...

Page 7: ...or low combustion Lit Digital indicator shows current temp Flashing Current temp can be changed Lit Digital indicator shows current day or timer day Three speed motor supplies high capacity warm air...

Page 8: ...the tank Stop filling by loosening the switch button on top of the pump turn anti clockwise once the gauge indicates that the tank is full Never overfill the tank especially not when the fuel is very...

Page 9: ...other days of the week will go off Select a day of the week by using the MIN or the HOUR button When pressing the MIN button the sign will change as follows SUN MON TUE WED THU FRI SAT When pressing t...

Page 10: ...erature under 0 C 4 minutes 0 C 15 C 2 minutes 15 C 1 5 minutes 2 Adjusting Room Temperature A Press the MIN or HOUR button F or C will start to flash NOTE The MIN or HOUR button will change the tempe...

Page 11: ...it you will hear an alarm signal every two minutes warning you to refill the removable tank After 10 minutes the information display fu el blinks and the heater will switch off automatically CHILD LO...

Page 12: ...position of P01 you can hear the beep sound and P01 is not changed any more Basically the only next program number of the biggest set program number is shown on the display and blinks All of 30 progr...

Page 13: ...he HOUR button will change temperature every 1 C 2 F Press the SET button to complete the set the temperature of the program and move to the next step Set a day of the week of the program 4 Set a day...

Page 14: ...ombustion mode High Medium or low manually regardless of room temperature 1 Press the MIN button and HOUR button at the same time for more than three 3 seconds when ON OFF switch is ON 2 P1 P2 or P3 w...

Page 15: ...n See Page 10 Clock and Day setting See Page 7 Auto operation See Page 13 Child lock operation See Page 10 TIME LENGTH OF POWER FAILURE OPERATION POWER SAVER OPERATION AUTO OPERATION CHILD LOCK OPERAT...

Page 16: ...to make sure connection is firm Use a vacuum cleaner to remove any dust or pet hair 4 Clean Fuel Acceptance Fitting When dirt or dust accumulates in the fuel acceptance fitting it should be cleaned Ch...

Page 17: ...n and clock is set See Set Clock on page 7 it will automatically stop and clean the igniter every day at 2 00 and will display CL on the digital indicator After the cleaning mode is finished the heate...

Page 18: ...peration Normal Normal Wipe off any paraffin spills from fuel sub tank removable fuel tank and drip tray Remove fuel and refuel using fresh water clear paraffin SECTION G TROUBLESHOOTING ERROR CODE E...

Page 19: ...e once again using a dry cloth d Cover heater completely with a large plastic bag to protect from dust 4 To store heater in another location a Disconnect heater b Remove all fuel from the fuel sub tan...

Page 20: ...eater For alternate installation methods you may need to purchase additional accessories which are available from your TOYOTOMI dealer See Accessory Parts SECTION I INSTALLATION L shaped Hose 2 PART 1...

Page 21: ...90 bends Elbows If the distance between the heater and the Flue Pipe is greater than 3 m then the proposed installation is unsuitable At the exhaust end of Extension pipe kits L M and S the Flue Pipe...

Page 22: ...n Outer Intake Pipe 1000 mm PART 17206092 Intake Pipe Joint PART 17206091 Intake Pipe 2000 mm 90 mm Total length of extension pipe between heater and Flue Pipe must be no greater than 3 m No more than...

Page 23: ...PIPE KIT L Adjustable Exhaust Pipe Insulation Cloth Cover Exhaust Extension Pipe long Pipe Holder Intake Hose Pipe Support Hardware 17187098 17212685 17206004 17206027 17206089 17206091 17206025 Pipe...

Page 24: ...206057 17206091 17206025 6 1 2 3 Max 500 mm Min 320 mm 500 mm 500 mm Flue pipe connection Intake Hose Heater Exhaust pipe connection Figure 2 Flue pipe connection Intake Hose Heater Exhaust pipe conne...

Page 25: ...d does not normally present any problems 3 Before making a hole in the wall for the Flue Pipe ensure the wall cavity is free of electrical wires gas pipes and other obstacles Drilling a 5 mm pilot hol...

Page 26: ...ough the wall of any conventional building cladding including Brick Hebel Linear Gibraltar and Plaster Board Tiles Weatherboard Plastered Polystyrene and metal profiles etc C The FF 55T heater is desi...

Page 27: ...he extension wire optional is available to change the location Please refer to the following procedure 1 Unfasten a screw to disassemble the sensor case on the cabinet with a driver 2 Remove the conne...

Page 28: ...Printed in Japan 8374002060 TOYOTOMI CO LTD 5 17 Momozono cho Mizuho ku Nagoya Japan http www toyotomi jp New 06 14 FF_55T_Type B_US qxd 14 5 29 15 58 27...

Reviews: