ERROR CODE

E-0
E-2
E-6
E-8

E-12
E-13

E-22
E-23

-- : --

Hi

Lo

INFORMATION

Power interrupted.
Ignition safety feature is activated.
Extinguished during operation.
Blower motor malfunction.
Overheating safety feature is activated.
Burner thermistor malfunction
Excess fuel in the burner
Ignition failure three times
Primary flame (Flame sensor) is malfunction and / or dirty.
Timer is not setting.
Room temperature is higher than 35˚C.
Position of room temperature sensor is not correct.
Room temperature is lower than -10˚C.
Room thermistor malfunction or disconnected.

WHAT TO DO

Re-ignite the heater
Contact your dealer
Contact your dealer
Contact your dealer
Clean the air filter and remove dust.
Contact your dealer
Contact your dealer
Contact your dealer
Contact your dealer.
Set the timer.
Check the position of room temperature
sensor.
Check the position of room temperature
sensor.

SECTION E:

ERROR MESSAGE

Step 4:  Look  for  the  source  of  the  overheating. 

Overheating is usually caused by objects that 
obstruct  the  free  flow  of  air.    Check  that  the 
circulation  ventilator  or  exhaust  pipes  are  not 
blocked.  Check  that  there  are  no  objects 
blocking the outlet system.

Step 5:  Remove the front panel.
Step 6:  Clean the inside of the heater.

Before  starting  to  clean  the  heater,  ensure 
that  the  interior  is  cool  enough  to  touch.  
Wipe  alldust  off  the  outside  of  the  housing 
with a clean,non-fluffy, damp cloth or another 
suitable cleaning aid.  Do not forget to clean 
the out side of the heat chamber and the heat 
exchanger.

Step 7:  Re-attach the front panel.
Step 8:  Insert the heater plug into the socket.
Step 9:  Switch the heater ON.
Step 10:  Re-program the heater (clock and timer).

If the heater overheats after the completion of 
a  recovery  procedure,  contact  your  dealer 
and  do  not  switch  the  heater  on  until  the 
problem has been resolved.

10. Cleaning the filter (monthly)

Switch  off  the  heater  and  let  it  cool  down,  before  you 
start  any  maintenance  work.  Also  disconnect  the  plug 
from the mains.
Your  needs  hardly  any  maintenance.  It  is,  however, 
important  that  you  clean  the  louvers,  grilles  and 
circulation  fancover  on  the  back  of  the  heater  weekly. 
Periodically checkthe flue pipe connection for leakage or 
separation.

We recommend that you remove dust and stains in time 
with a damp cloth, because otherwise these may cause 
stains that are hard to remove.

Do  not  remove  any  heater  components 
yourself.  Always  contact  your  dealer  for 
repairs.  Whenthe  power  cord  is  damaged,  it 
may  only  bereplaced  by  an  authorized  fitter.  
Use a new cordof the type H05 VV-F.

11. Before consulting an expert

The following situations do not indicate defects.

While switching the heater on or off.

White smoke can be seen when the heater is switched 
on for the first time.

Machine  oil  or  dust  on  the  burner  chamber  or  heat 
exchanger is burning.

The  flames  flicker  for  several  minutes  after  the  heater 
has been ignited.

The ignition rod continues to function when the heater is 
cold, even several minutes after ignition. This may cause 
the flames to be a little larger.

The  heater  makes  intermittent  creaking  sounds  when 
warming up or cooling down.

Expansion  and  shrinkage  of  metal  parts  may  cause  a 
slight creaking sound.

Circulation of air in the room does not start immediately 
when the heater is lit.

To prevent unpleasant cold draughts, the ventilator only 
switches on when the heater has become warm.

A loud clicking sound can be heard during the first use 
or when the fuel runs out.

There is air in the fuel pump. This should be gone within 
approximately 1 minute.

Note:  The  fuel  pump  may  make  a  slight 
ticking  sound  during  normal  operation.  This 
does not indicate a problem.

While the heater is in operation

A part of the burner pot and/or heat exchanger becomes 
red  in  color  during  operation.  This  is  normal  and  does 
not indicate a problem.

Summary of Contents for FR-700F

Page 1: ...CODES AND ORDINANCES FOR PERMITTED USE MODEL FR 700F CONTENTS SECTION A Specifications 2 SECTION B Safety Tips for Operation 3 SECTION C Fuel Guide 4 SECTION D Operation 5 SECTION E Error Messages 10 SECTION F Installation 11 SECTION G Fuel Storage and Supply System 23 VENTED HEATING SYSTEM INSTALLATION AND OPERATION INSTRUCTIONS ...

Page 2: ...e only Dimensions W H D 700 593 422 mm Weight 28 kg Vent Pipe Hole 70 80 mm diameter Maximum Length of Vent Pipe System 3 m 3 bents or less Electrical Rating 220 Volts AC 50 Hz Preheat 260 W Burning 45 W 1 Heat and vaporized water are produced by the combustion process of this heater This rating does not take into account heat loss due to condensation of water vapor 2 External tank to be purchased...

Page 3: ... flames resulting in destructive fire 2 Due to high surface temperatures keep heater away from children furniture and clothing while in operation See Page 12 3 To prevent abnormal operation and prolong heater life be sure to perform routine maintenance See Pages 9 4 Never store or transport fuel in other than a metal or plastic container that is 1 acceptable for fuel and 2 clearly marked KEROSENE ...

Page 4: ...when optional removable fuel tank is used ALWAYS Fill heater away from living quarters when heater is cool use siphon ALWAYS Watch fuel gauge to avoid overfilling heater How to Store It ALWAYS Store in a clean container clearly marked KEROSENE ALWAYS Store away from direct sunlight heat sources or extreme temperature changes NEVER In a glass container or one that has been used for other fuels NEVE...

Page 5: ...egulates the room temperature uses very little fuel and electricity and has options for automatic or manual operation This section provides all the information required for the operation of the Vented heating system All specified operating procedures must be carried out in the order in which they are described SECTION D OPERATION ...

Page 6: ...to set the Automatic operation The heater will operate automatically in accordance with the set and room temperature 2 Operating elements and lights 5 SAVE button Allows you to limit the temperature When this function is activated the heater will automatically switch off and on again 6 TIMER button Allows you to switch on the heater automatically at a preset time 7 CHILDPROOF LOCK button Can be us...

Page 7: ...nsert the plug into the wall socket 220 Volts AC 50Hz Step 5 Setting the clock Important The clock on the heater must always be set to the correct time It is only possible to set the correct time when the heater is connected to the mains and not burning Use the adjustment buttons to set the time First press either of the two buttons to switch on the function empty full the CLOCK light and the info...

Page 8: ...ep After approximately 10 seconds the light will stop blinking and setting will belocked The available temperature settings range from10 C minimum to 32 C maximum When the heater has been unplugged or after a power failure the temperature will reset to the factory setting of 20 C The operating mode is automatically controlled in accordance with the room temperature detected by the room temperature...

Page 9: ...ildproof lock The childproof lock can be used to prevent children accidentally changing the heater settings When the heater is burning and the childproof lock is on the heater can only be switched off Other functions are blocked then If the heater has already been switched off the childproof lock also prevents accidental ignition of the heater Activate the childproof lock by pressing the appropria...

Page 10: ...ime with a damp cloth because otherwise these may cause stains that are hard to remove Do not remove any heater components yourself Always contact your dealer for repairs Whenthe power cord is damaged it may only bereplaced by an authorized fitter Use a new cordof the type H05 VV F 11 Before consulting an expert The following situations do not indicate defects While switching the heater on or off ...

Page 11: ...on and or dirty Timer is not setting Room temperature is higher than 35 C Position of room temperature sensor is not correct Room temperature is lower than 10 C Room thermistor malfunction or disconnected WHAT TO DO Re ignite the heater Contact your dealer Contact your dealer Contact your dealer Clean the air filter and remove dust Contact your dealer Contact your dealer Contact your dealer Contac...

Page 12: ...ust be kept free for air circulation The Vented Heating System can be placed on any type of flooring and operate safely unless fuel or fire safety regulations specify otherwise Check the gaps in the manner stipulated in the instructions in the manual Recommended tool kit 1 Crosshead screwdriver 2 Steel tape measure 3 Felt tip pen or pencil 4 Cement for exterior use 5 Electric drill clockwise and a...

Page 13: ...re indications 5 Unpacking Save all packaging materials for possible future transportation A Remove the cardboard drilling template and the user s manual from the packaging B Remove the drip tray from the packaging C Remove the box with the installation kit from the packaging D Remove the heater from the packaging E Remove the plastic bag containing the parts F Remove the exhaust pipe from the bot...

Page 14: ...t Not less than 60 cm Combustible object Noncombustible object Not less than 60 cm Not less than 30 cm Flue pipe Not less than 20 cm 45 Be sure this clearance will be maintained after snowfalls etc Not less than 45 cm Frontal obstruction 45 cm or more Snow covered surface or ground 50 cm or more Must be higher Extension tube of max 2 5 metres Snow Windbreaker Not less that 45 cm Strong wind Distan...

Page 15: ... the heater has to be moved these are the dimensions and locations of the holes for the fuel pipe and exhaust pipe Do not remove any components from the heater Always contact your dealer if repairs are required If the electricity cable is damaged this may only be replaced with type H05 VV F and by a recognised installer 638 244 202 Hole for wall bracket 220 552 286 264 99 80 86 212 61 Contre of th...

Page 16: ...of standard installation parts is sup plied with your heater It may be necessary to order extra parts from your dealer if other installation methods are required L shaped hose 2 Pipe holder 1 Pipe stopper 1 Flue pipe 1 Bent joint 1 Wall bracket 2 set 3 ...

Page 17: ...16 Hose band 2 Drip tray 1 Top guard assembly 1 Oil catch 1 Inlet hose 1 ...

Page 18: ...tle higher than the opening on the outside in order to create a slight gradient in the feed through and flue pipe after installation approximately 2 see Fig 3 This ensures that condensed water in the flue pipe flows to the outside and prevents the penetration of rainwa ter and snow after installation Comment The heater must be installed on a strong and stable floor The floor must be flat and level...

Page 19: ...w Inside Outside 2 downward Min 130 230 mm c From outside insert the outer flue pipe through the hole Secure the outer flue pipe to the wall by turning it clockwise This locks the two halves together See Fig 5 IMPORTANT Make sure the arrow on the outer flue pipe frange is pointing up Make sure to secure the outer flue pipe well A part shown in Fig 5 Fig 5 Inner flue pipe Inside Outside 2 downward ...

Page 20: ...aps provided with the heater Make sure the caps fit tightly onto the opening See Fig 6 NOTE If the inlet hose is not smoothly inserted into the L shaped hose apply water or soap suds to the inlet hose 5 Move the heater into position Connect the bent joint to the exhaust outlet opening upper opening and attach the L shaped hose to the intake inlet opening Make sure all connections are tight See Fig...

Page 21: ... extension pipe to the exhaust outlet opening by sliding the pipe stopper in the exhaust opening bracket See Fig 8 7 Make sure the position of the heater is level by using the plumb bob located at the right side of the heater The plumb bob weight should be within the circle If the plumb bob weight is not within the circle adjust the heater legs until the plumb bob weight is within the red circle S...

Page 22: ... heater to ensure that the airflow to the air circulation ventilator is notobstructed Inspect the interior of the building to ensure that the area immediately adjacent to the heater is free of fuel and objects that may obstruct the free flowof air Check that the room sensor is not exposed to draughts direct sunlight or heat radiated directly from the heater Use a spirit level to check that the hea...

Page 23: ...ificant heat sources Fuel Tank contents must not exceed 40 C in normal operation 8 Only use clean new soft drawn copper tubing for fuel line 8 mm or 5 16 OD If necessary to braze joint extend copper tube ensure that internal scale caused by brazing is blown away with dry compressed air dry nitrogen CO2 or by allowing at least three liter s of diesel to flow through the pipe to wash away internal c...

Page 24: ...TOYOTOMI CO LTD 5 17 Momozono cho Mizuho ku Nagoya Japan New 07 16 Printed in Japan 2267002060 ...

Reviews: