SECTION A:
SPECIFICATIONS
Model:
Heater Efficiency:
Heat Rating:
Fuel Consumption:
Fuel System:
Fuel Type:
Dimensions (W
´
H
´
D):
(Includes drip tray)
Weight:
Vent Pipe Hole:
Maximum Length of Vent Pipe System:
Electrical Rating:
Typical Room Size (3):
Laser 60AT
90% (1)
High - 30,000 BTU/h (8,800 Watts)
Med - 21,000 BTU/h (6,160 Watts)
Low - 12,000 BTU/h (3,520 Watts)
High - 0.230 gal/h (0.870 L/h)
Med - 0.161 gal/h (0.609 L/h)
Low - 0.095 gal/h (0.360 L/h)
External tank (2)
ASTM D3699 1-K Kerosene, ASTM D396 Low Sulfur No.1
Fuel Oil, or ASTM D975 Ultra Low Sulfur Diesel (ULSD)
30“
´
24“
´
19“
(76.0
´
60.8
´
48.3 cm)
77 lbs. (35 kg) Empty
2-3/4“ ~ 3“ diameter
(7.0 - 7.5 cm)
10 ft. (3 m), 3 bends or less
120 Volts AC, 60 Hz
Preheat - 280W
Burning - 60W
1250 square feet (0˚F)
1500 square feet (20˚F)
(1)
(2)
(3)
Heat and vaporized water are produced by the combustion process of this heater. This rating does not
take into account heat loss due to condensation of water vapor.
External tank to be purchased from local suppliers.
0˚ F Heat Load
= 24 BTU/ft
2
/hr
20˚ F Heat Load = 20 BTU/ft
2
/hr
Room size for which this heater is suitable will vary depending on outside temperature, house
insulation, window size, and other factors.
2