JetStream L2 Managed Switch
07
Introduction
For T2600G-28TS-DC
The rear panel is shown as the following figure.
Figure 1-12
Rear Panel of T2600G-28TS-DC
DC Power Input
Grounding Terminal
Kensington Security slot
Kensington Security Slot
Secure the lock (not provided) into the security slot to prevent the device from being stolen.
Note:
TL-SG5412F/T2500-28TC does not have a kensington security slot.
Grounding Terminal
The switch already comes with lightning protection mechanism. You can also ground the switch
through the PE (Protecting Earth) cable of AC cord or with Ground Cable. For detailed lightning
protection measures, go to https://www.tp-link.com/support, search the model number of your
switch and go to the product
Support
web page, refer to the
Lightning Protection Guide
from the
Related Documents
:
https://www.tp-link.com/us/configuration-guides/lightning_protection_guide/
Power Socket
Plug the negative connector of the power cord directly into the power socket and plug the positive
connector into an AC power outlet. Make sure that the voltage of the power supply meets the
requirement of the input voltage (100-240V~ 50/60Hz).
Note:
You should use the provided power cord.
DC Power Input
Attach the power wires to the DC power input. We recommend you use 22-14 AWG wires. Connect
the positive pole of the DC power supply to the "+" end, and the negative pole to the "-" end. Make
sure the power supply meets the requirement of the input (18-48V 1.2A). A disconnecting device
like an isolating switch shall be installed and easily accessible. The disconnecting device shall have a
contact separation at least equal to the minimum clearance for basic insulation.
Note:
The power wires and disconnecting device are not included with our product. If needed, you
can purchase them separately.