JetStream L2 Managed Switch
15
Connection
3.5 Power On
For TL-SG5412F/T2500G-10TS/T2500G-10MPS/T2500-28TC/T2600G-18TS/T2600G-28TS/
T2600G-28MPS/T2600G-28SQ/ T2600G-52TS
Plug the negative connector of the power cord directly into the power socket and plug the positive
connector into an AC power outlet as the following figure shows. Make sure that the voltage of the
power supply meets the requirement of the input voltage (100-240V~ 50/60Hz).
Figure 3-5
Connecting to the Power Supply
100-240V~50/60Hz 0.5A
Note:
The figure is to illustrate the application and principle. The provided plug and the socket in your
region may differ from the figures above.
For T2600G-28TS-DC
Attach the power wires to the DC power input as the following figure shows. We recommend you use
22-14 AWG wires. Connect the positive pole of the DC power supply to the "+" end, and the negative
pole to the "-" end. Make sure the power supply meets the requirement of the input (18-48V 1.2A). A
disconnecting device like an isolating switch shall be installed and easily accessible. The
disconnecting device shall have a contact separation at least equal to the minimum clearance for
basic insulation.
Figure 3-6
Connecting to the Power Supply
To a disconnecting device
and DC power supply
Note:
The figure is to illustrate the application and principle. The power wires and disconnecting
device are not included with our product. If needed, you can purchase them separately.