The Power LED should be lit when the power system is working normally. If the
Power LED is not lit, please check as follows:
A1:
Make sure the AC power cord is connected to the switch with power source
properly.
A2:
Make sure the voltage of the power supply meets the requirements of the
input voltage of the switch.
A3:
Make sure the power source is ON.
Standard
IEEE802.3i, IEEE802.3u, IEEE802.3ab,
IEEE802.3ad, IEEE802.3af, IEEE802.3x,
IEEE802.1p, IEEE802.1q, IEEE802.1d,
IEEE802.1s, IEEE802.1w, IEEE802.3z
CSMA/CD
Ethernet:10Mbps (Half Duplex) 20Mbps (Full Duplex)
Fast Ethernet: 100Mbps (Half Duplex) 200Mbps (Full Duplex)
Gigabit Ethernet: 2000Mbps (Full Duplex)
10Base-T:
UTP Cat. 3, 4, 5 cable (maximum 100m) EIA/TIA-568 100
Ω
STP (maximum 100m)
100Base-TX:
UTP of Cat. 5 or above (maximum 100m)
EIA/TIA-568 100
Ω
STP (maximum 100m)
1000Base-T:
UTP of Cat. 5e or above (maximum 100m)
EIA/TIA-568 100
Ω
STP (maximum 100m)
8 10/100/1000Mbps Auto-Negotiation RJ45 ports and 2
SFP slots
PoE Ports: Port1-Port8
Total Power Supply: 53W
Power, System, Link/Act, PoE MAX, PoE Status, SFP1, SFP2
Store and Forward
Automatically learning, automatically aging
10Base-T: 14881pps/Port
100Base-Tx: 148810pps/Port
1000Base-T: 1488095pps/Port
10Base-T: 14881pps/Port
100Base-Tx: 148810pps/Port
1000Base-T: 1488095pps/Port
Protocol
Data Transfer Rate
Network Media (Cable)
Number of Ports
LED Indicators
Transfer Method
MAC Address Learning
Frame Filter Rate
Environmental and Physical Specifications
Operating Temperature
Storage Temperature
Operating Humidity
Storage Humidity
0˚C to 40˚C (32˚F to 104˚F)
-40˚C to 70˚C (-40˚F to 158˚F)
10% to 90% non-condensing
5% to 90% non-condensing
Frame Forward Rate
PoE Ports (RJ45)
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant
to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful
interference when the equipment is operated in a commercial environment. This equipment generates,
uses, and can radiate radio frequency energy and, if not installed and used in accordance with the
instruction manual, may cause harmful interference to radio communications. Operation of this
equipment in a residential area is likely to cause harmful interference in which case the user will be
required to correct the interference at his own expense.
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
1) This device may not cause harmful interference.
2) This device must accept any interference received, including interference that may cause undesired
operation.
Any changes or modifications not expressly approved by the party responsible for compliance could
void the user’s authority to operate the equipment.
FCC STATEMENT
Do not use this product near water,
for example, in a wet basement or
near a swimming pool.
Avoid using this product during an
electrical storm. There may be a
remote risk of electric shock from
lightning.
SAFETY NOTICES
Cautions
This is a class A product. In a domestic
environment, this product may cause radio
interference, in which case the user may
be required to take adequate measures.
CE Ma
r
k Wa
r
nin
g
© 2017 TP-Link
Industry Canada Statement
CAN ICES-3 (A)/NMB-3(A)
Explanation of the symbols on the product label
DC voltage
RECYCLING
This product bears the selective sorting symbol for Waste electrical and electronic equipment
(WEEE). This means that this product must be handled pursuant to European directive
2012/19/EU in order to be recycled or dismantled to minimize its impact on the environment.
User has the choice to give his product to a competent recycling organization or to the retailer
when he buys a new electrical or electronic equipment
General Specifications
Frequently Asked Questions (FAQ)
Q1. The Power LED is not lit.
Please try the following:
A1:
Make sure that the cable connectors are firmly plugged into the switch and
the device.
A2:
Make sure the connected device is turned on and works normally.
A3:
Try to change the connected device’s transmission speed and duplex mode.
A4:
The cable must be less than 100 meters long (328 feet).
Q2. Why is the Link/Act LED not lit while a device is connected to
the corresponding port?
Q3. Why are some ports not supplying power for PoE devices?
Please try the following:
A1:
Make sure that this PoE device complies with IEEE 802.3af/IEEE 802.3at.
A2:
Try another PoE port on the switch.
A3:
Pay attention to PoE priority. If the total power consumption of PoE powered
devices exceeds 53W, a priority will be set among the ports. Ports with a smaller
port number will have higher priority. For example, Port 1, 2 and 5 are each
consuming 15.4W. If an additional powered device consuming 12W is connected
to Port 3, then the switch will cut off power to Port 5 because of the overload.
Specifications
Продукт сертифіковано згідно с
правилами системи УкрСЕПРО
на відповідність вимогам
нормативних документів та
вимогам, що передбачені
чинними законодавчими актами
України.
安全諮詢及注意事項
請使用原裝電源供應器或只能按照本產品注明的電源類型使用本產品。
清潔本產品之前請先拔掉電源線。請勿使用液體、噴霧清潔劑或濕布進行清潔。
注意防潮,請勿將水或其他液體潑灑到本產品上。
插槽與開口供通風使用,以確保本產品的操作可靠並防止過熱,請勿堵塞或覆蓋開口。
請勿將本產品置放於靠近熱源的地方。除非有正常的通風,否則不可放在密閉位置中。
請不要私自打開機殼,不要嘗試自行維修本產品,請由授權的專業人士進行此項工作。
此為甲類資訊技術設備,于居住環境中使用時,可能會造成射頻擾動,在此種情況下,使用者會
被要求採取某些適當的對策。
BSMI Notice
For technical support and other information, please visit
http://www.tp-link.com/support
この装置は、クラスA情報技術装置です。この装置を家庭環境で使用すると電波妨害を引き起こすことがあり
ます。この場合には使用者が適切な対策を講ずるよう要求されることがあります。 VCCI-A