14
13
3.
Specifications (cont.)
l. General Specifications
Max. volt. between
1000V
any input and Ground
Fuse protection
mA :
0.5A/600VAC;
A :
10A/600VAC
Display Type Digital : 50000 count, 4 times/S update Bar
graph : 51 segment
Operating temp.
0°C to 40 °C (32°F to 113°F)
Storage Temp.
-20°C to 60°C (-4°F to 140°F)
Relative Humidity
0% to 80% ( 0° ~ 35 °C/ 32° ~ 95°F)
0% to 70% ( 35° ~ 55 °C/ 95° ~ 131°F)
Power Supply
9Volt battery
Battery Life
Size(H x L x W)
Weight
3.
Specifications (cont.)
i. Current Output
Mode
Range
Accuracy
Source
0~24mA
0.1% of reading, +/- 10digits
Smulate
0~24mA
h. Continuity Buzzer
Test voltage
Threshold
Overload protection
3V
30digits
600V DC or AC peak
j. Frequency
Range
Resolution
Accuracy
Overload protection
500Hz
0.01Hz
+/-0.05% of reading, 600V DC or AC
5Khz
0.0001Khz
+/- 5digits
peak
50Khz
0.001Khz
500Khz
0.01Khz
k. Adaptor
Model
Display
A301(Temp Adaptor C/F)
1mV/C, 1mV/F 0000.0 C/F
A254(Current Adaptor 10/60A)
100mV/A,
00.000A
10mV/A
000.00A
A256(Current Adaptor 40/400A)
1mV/A
0000.0A
A296(Current Adaptor 400/1000A) 1mV/A
0000.0A