background image

 

 

SP323 Smart Temperature Clamp Probe 

Instruction Manual

 

 

 

 

 

 

 

 

 

Scan to download  

 

the TPI View app:  

 

 

Summary of Contents for SP323

Page 1: ...SP323 Smart Temperature Clamp Probe Instruction Manual Scan to download the TPI View app ...

Page 2: ...UPERHEAT SUB COOLING Connecting two SP670 s and two SP323 smart temperature clamps allow superheat and sub cooling to be calculated 1 Turn on each SP670 and SP323 open the app and allow the smart probes to connect 2 Connect the probes to the Suction low side and Liquid high side lines 3 Tap on Refrigeration in the app For the Suction Line tap on Pressure Select to assign the SP670 connected to the...

Page 3: ...o points Using One SP323 1 Select DIFF TEMP 1 DEVICE in the app Connect the SP323 to the test point and wait for the temperature to stabilize 2 Tap on the reading to hold the temperature Connect the SP323 to the next test point and allow the temperature to stabilize 3 Tap on the reading to hold temperature 2 The bottom display will read the difference between temperature 1 and temperature 2 4 A re...

Page 4: ...ected and logging is stopped When the SP323 is in logging mode and disconnected from the View app the SP323 LED will blink green and orange 7 Once logging has been stopped or ended logged data can be retrieved using the View app GENERAL MAINTENANCE Housing The SP323 can be wiped down with a damp lint free cloth Do not use any cleaning agents including solvent or soap Battery Replacement When the L...

Page 5: ... 10 000 readings in 1 sec to 59 min 59 sec intervals Battery Life Approximately 170 hours Battery Type AAA x 3 alkaline Operating Temperature 32 F 122 F 0 C 50 C Storage Temperature 4 F 140 F 20 C 60 C Humidity 0 80 RH Weight 5 64oz 160g Bluetooth 5 0 350 foot range depending on obstacles See www tpieurope com for CE and UKCA Certificate of Conformity FCC ID QOQBGM113 IC Industry Canada ID 5123A B...

Page 6: ...ation of incidental or consequential damages so the above limitations or exclusions may not apply to you To Obtain Warranty Performance Include with the product your name address phone number written description of the problem and proof of purchase date Carefully package and return to TPI Inc TPI Canada TPI Europe Ltd 9615 SW Allen Blvd 342 Bronte Rd S Unit 6 Unit 6 Beaverton OR 97005 Milton Ontar...

Page 7: ...NOTES ...

Page 8: ...www testproductsintl com Test Products International Ltd 342 Bronte Road South Unit 6 Milton Ontario Canada L9T 5B7 Tel 905 693 8558 www tpicanada com Test Products International Europe Ltd Rutherford Way Industrial Estate Rutherford Way Manor Royal Crawley West Sussex RH10 9LN www tpieurope com ...

Reviews: