Assembly Instructions | ILM Servo Kits
20
Edition 03/2021 EN
Assembly
DANGER
Danger of death by electric shock or arcing at the power connections of the
ILM servo kit
The contacts of the power connections carry potentially fatal voltages and high current
strengths. Removing the cables to the power connections of the ILM servo kit during oper-
ation can cause arcing, resulting in serious or fatal injury.
Depending on the installed buffer capacity, the DC link of a connected inverter can contin-
ue to carry dangerous voltages for some time, even after the power supply to the entire
system is switched off.
►
Never detach electrical connections on the ILM servo kit or the inverter while they are
live.
►
Use a permitted meter to check that the power connections are voltage-free before
you carry out installation work on the device.
WARNING
Danger of eye injuries caused by splintering magnetic parts
The rotors of the ILM servo kit will attract other magnetic materials. The forces of attraction
can be so great that the magnets of the servo kit splinter on impact and tiny fragments fly
into the eyes.
►
Wear safety goggles to protect your eyes until you have finished installing the
ILM servo kit.
►
Keep the rotors of the ILM servo kit away from other magnetic materials.