Logger menu 

— 

User Settings… 

2.4
Use this option to specify the following settings in Ideal Finish Analysis. 

 

Select the logging interval time 

 

Specifying the time 

-

 

Check the Synchronize check box. This will set the data logger time to the PC time 

 

Setup the batch names 

-

 

Double click on the current name to enter a new batch name 

 

Set the paint types in your logger 

 

Set the cure specifications for the report 

 

Configure the properties when logging data in Real Time. 

-

 

Enter a description of the object you are measuring and enter a description of the 
location where the measuring takes place. 

 

Logger menu 

— 

Configure & Test… 

2.5
In order for the data logger to communicate with a computer, use the USB cable to connect it 
to an available port on the computer. Once connected, communication can be tested by 
taking the following steps: 

Step 1.

 

Connect the data logger to the computer using the cable that comes with the 
logger. 

Step 2.

 

Choose Configure & Test…

¹

 from the Logger menu. 

Step 3.

 

The logger starts measuring automatically, displaying the measurements

²

 in a pop-

up window. 

Step 4.

 

Click More to see information about the connected logger, click OK or Cancel to 
close the pop-up window. 

 

¹  

If an error message is displayed, switch to another USB port. If all ports display an error 
message, make sure that the rechargeable battery is charged and the data logger is 
powered on. 

 
²

 Measurements will be shown even when no probes are connected. This is normal behavior 

and are the internal cold junction temperature measurements.

 

Summary of Contents for CurveX 3 Basic

Page 1: ...1 CurveX 3 Basic Article number CX3005 User Guide V1 1 0916...

Page 2: ...rom natural wear and tear mechanical or chemical damage an act of God or non compliance with the operating instructions shall be excluded from the warranty as well as mechanical interference by the cu...

Page 3: ...ress 7 2 2 Logger menu Real Time 7 2 3 Logger menu User Settings 8 2 4 Logger menu Configure Test 8 2 5 3 The CurveX 3 Basic thermocouple connectors 9 3 1 1 Connecting the probes 9 4 CurveX 3 Basic pr...

Page 4: ...uple probes to the input points at position 7 of the CurveX 3 Basic Step 3 Attach the sensors to the object to be measured Step 4 Press and hold down the POWER button position 1 for one second to swit...

Page 5: ...ogging led Blue led indicates CurveX 3 Basic is logging 5 Paint led Red partial cure Blue active Green full cure 6 Battery led Shows battery status when powered on Red 25 Blue 25 to 75 Green 75 7 Ther...

Page 6: ...rtly used Loggings that take longer than 16 000 readings are stopped at reading number 16 000 The maximum number of batches that can be stored is 10 CurveX 3 Basic tasks 1 3 This table below describes...

Page 7: ...ing the POWER button see figure 1 position 1 and start the Ideal Finish Analysis software Step 2 Connect the USB connector to the CurveX 3 Basic see figure 1 position 8 Step 3 Connect the other side o...

Page 8: ...communicate with a computer use the USB cable to connect it to an available port on the computer Once connected communication can be tested by taking the following steps Step 1 Connect the data logger...

Page 9: ...ial infrared probes Figure 2 The position of the sensors on the object can be stored in Ideal Finish Analysis The position will then also be available in the reports Remark Make sure that the probe ca...

Page 10: ...is part in order to align the sensor element with the surface to ensure good contact Take the clamp between your thumb and forefinger Check which jaw has the sensor element and place the probe at the...

Page 11: ...datasheet for the maximum time and temperature use 4 1 1 Preparing for measurement Step 1 Make sure the box is at room temperature Step 2 Place the CurveX 3 Basic data logger with the probes already c...

Page 12: ...cabin The battery employed in our CurveX 3 Basic is a generic single cell Lithium Ion battery 3 7V 1400mAh The battery employed in the CurveX 3 Basic has a capacity of 5 18 Watt hours and is rated fo...

Page 13: ...by Weight 190 g 6 7 oz TQC Ideal Finish Analysis software Supported Operating Systems Windows Vista Windows 7 and Windows 8 8 1 Platform 32 b or 64 b Memory 32 MB Required Hard Disk space 128 MB Curve...

Page 14: ...14...

Page 15: ......

Page 16: ......

Reviews: