Parameterization via TRWinProg
TR-Electronic GmbH 2011, All Rights Reserved
Printed in the Federal Republic of Germany
Page 50 of 55
TR - ECE - BA - DGB - 0084 - 05
06/28/2017
4.2.4 For the position output valid parameters
Start and final value in steps:
With the parameters
start value in steps
and
final value in steps
it
can be defined the pos-range within the programmed
total number of steps
.
Thereby the start value must be defined smaller than the final value and the final value
smaller than the maximum position value.
Start and final value in mV:
With the parameters
start value in mV
and
final value in mV
it can be
defined the U-range within the maximum voltage values. Thereby the start value must
be defined smaller than the final value.
Example:
Figure 9: Definition of the active range (voltage / position)
Legend
U
O
= actual measured output voltage [V] *
U
max
= maximal possible output voltage [V] *
U
SV
= programmed
start value
of the voltage
in mV
*
U
FV
= programmed
final value
of the voltage
in mV
*
Pos
= actual position of the measuring system [steps] *
Pos
max
= by the parameter
total number of steps
programmed
measuring length plus the
origin type
*
Pos
SV
= programmed
start value
of the position
in steps
*
Pos
FV
= programmed
final value
of the position
in steps
*
* signed