Troubleshooting and diagnosis options
TR-Electronic GmbH 2016, All Rights Reserved
Printed in the Federal Republic of Germany
Page 100 of 103
TR - ECE - BA - DGB - 0131 - 02
10/31/2018
7.2.2.2 Operating status
Bit
Meaning
= 0
= 1
E
x
te
nd
e
d di
a
gno
s
is
, by
te
9
Bit 0
Code sequence
Increasing CW
Increasing CCW
Bit 1
Class-2 functions
No, not supported
Yes
Bit 2
Diagnosis
No, not supported
Yes
Bit 3
Status scaling function
No, not supported
Yes
Bit 4
Not applicable
Bit 5
Not applicable
Bit 6
Not applicable
Bit 7
Not applicable
7.2.2.3 Encoder type
Extended diagnosis, byte 10
Code
Meaning
00
Single-turn absolute encoder (rotary)
01
Multi-turn absolute encoder (rotary)
See encoder profile for other codes
7.2.2.4 Single-turn resolution
Extended diagnosis, byte 11 - 14
Via this bytes the hardware single-turn resolution of the measuring system can be read
out.
7.2.2.5 Number of resolvable revolutions
Extended diagnosis, byte 15 - 16
Via this bytes the maximum number of measuring system revolutions can be read out.
Single-turn measuring systems report 1 revolution. Multi-turn measuring systems can
measure 12 or 16 revolution bits (see rating plate). If this value with 16 bits is not
representable, 0 is reported.
7.2.2.6 Additional alarms
This byte is reserved for additional alarms, although no other alarms are implemented.
Extended diagnosis, byte 17
Bit
Meaning
= 0
= 1
Bit 0-7
Reserved