5.8 Equipotential bonding
Example illustration
Figure 1: Ground point
A
: M5 thread for equipotential bonding
Position and execution can be found in the customer-specific pin assignment.
Shielded connecting cables must be used during installation. Please note that an electrical connection
exists between the shielding braid of the connecting cables used and the housing of the drive.
The shielding braid of the connecting cables must be grounded on both sides. These connections
must have “EMC-compliant” installation (low inductance, large surface).
The equipotential bonding is generally installed on the drive side using the thread of the connecting
plug and the M5 grounding plug.
Painting or coating the contact points and threaded parts of the connecting plugs is not permitted.