9 Emergency Message
Emergency messages are triggered by the occurrence of a device internal malfunction
and are transmitted from the concerned application device to the other devices with
highest priority.
Emergency Message
Byte
0
1
2
3
4
5
6
7
Contents
Emergency
Error Code
Object 1003h,
Byte 0-1
Error
Register
Object
1001h
0
0
0
0
0
COB-Identifier = 080h + Node-ID
If the measuring system detects an internal error, an emergency message will be
transmitted with the error code of object 1003h (pre-defined error field) and the error
register object 1001h. Additionally to the emergency object the according bit in the
Alarm object 6503h is set.
If the error disappears, the measuring system transmits an emergency message with