Printed in the Federal Republic of Germany
TR-Electronic GmbH 2010, All Rights Reserved
01/20/2017
TR - ELA - BA - DGB - 0016 - 04
Page 181 of 183
11.3 Emergency Error codes
Emergency objects are triggered by the occurrence of a device internal error situation,
transmission format see chapter “Emergency Message”, page 177.
The error indication is carried out about the objects
-
Error register 0x1001, page 152 and
-
Pre-defined error field 0x1003, page 153
11.3.1 Object 1001h: Error register
The error register displays bit coded the error state of the measuring system. Also
several errors at the same time can be displayed by a set bit. The error code of the
error occurred last is stored in object 0x1003, sub-index 1, the number of errors in
sub-index 0. An error is signaled at the moment of the occurrence by an EMCY-
message. With clearing of all errors the error register is reset and an EMCY-message
with error code "0x000" is transferred.
Bit
Meaning
0
generic error
1
0
2
0
3
0
4
0
5
device profile specific
6
0
7
0