8.4 Preset adjustment function
Risk of injury and damage to property by an actual value jump when the
Preset adjustment function is performed!
The preset adjustment function should only be performed when the
measuring system is at rest, otherwise the resulting actual value jump must
be permitted in the program and application!
Availability
TR-Mode
X
TR-Mode extended
X
In order that the preset adjustment function can be used, the function must be
activated, see chapter “Offset” on page 118!
The measuring system can be adjusted to an arbitrary position value within the
measuring range via the PROFIBUS.
This is achieved by setting the most significant bit 2
31
of the output data.
The preset adjustment value sent in the data bytes with the rising flank of the bit
"Preset execution"
is adopted as the position value.
There is no acknowledgement of the process via the inputs.
Lower limit
0
Upper limit
according to the adjusted resolution, related to 500 m