Parameterization and configuration
TR-Electronic GmbH 2011, All Rights Reserved
Printed in the Federal Republic of Germany
Page 118 of 139
TR - ELE - BA - DGB - 0022 - 04
02/08/2016
8.5.3 Measuring cycle
With the measuring cycle the sampling rate of the distance measuring is adjusted. The
value 0 adjusts automatically the fastest sampling rate. The measurement can need at
LLB-65 0.15 up to approx. 4 s and at LLB-500 0.04 up to approx. 4 s depends on the
surface condition. The value 0xFF deactivates this function and the laser diode is
switched off. 1 digit corresponds the time of one second. Thus, sampling rates of 1 s
to approx. 4 min. can be adjusted.
Availability
TR-Mode
X
TR-Mode extended
X
Lower limit
0x00
Upper limit
0xFF
Default
0x00
8.5.4 Count direction
Definition of the counting direction for the position value.
Availability
TR-Mode
X
TR-Mode extended
X
Selection
Description
Default
Positive
with increasing distance to the laser,
values increasing
X
Negative
with increasing distance to the laser,
values decreasing
8.5.5 Offset
Definition of the momentarily active function: Adjustment or Offset
Availability
TR-Mode
X
TR-Mode extended
X
Selection
Description
Default
Offset
Function in accordance with the description in
chapter “Offset value”, page 117.
X
Adjustment
Function in accordance with the description in
chapter “Preset adjustment function”, page 116.