Parameterization and Configuration
TR-Electronic GmbH 2018, All Rights Reserved
Printed in the Federal Republic of Germany
Page 122 of 167
TR - ELA - BA - DGB - 0027 - 03
11/12/2019
6.3.3.10 Encoder Class 4 functionality
Alternatively, this parameter can also be set during operation via acyclic parameter access to the
function control
PNU 65004
bit 1, see page 136.
Selection
Value Description
Default
disable
0
The parameters and functions
Scaling function
control
,
Preset
and
Code Sequence
are generally
disabled.
enable
1
The parameters and functions
Scaling function
control
,
Preset
and
Code Sequence
are generally
enabled.
The settings have a direct influence on the position output in
G1_XIST1
,
G1_XIST2
(if enabled via control word
G1_STW
,
bit 13) and
G1_XIST3
. The preset function is also only
effective in
G1_XIST1
, if the parameter
Preset affects
XIST1
is set to
enable
.
X
6.3.3.11 Preset affects XIST1
Alternatively, this parameter can also be set during operation via acyclic parameter access to the
function control
PNU 65004
bit 2, see page 136.
Selection
Value Description
Default
enable
0
The preset function, see page 145, is applied to the position
output in
G1_XIST1
, if
enable
is set in the parameter
Encoder Class 4 functionality
.
disable
1
The preset function has no effect on the position output in
G1_XIST1.
X
6.3.3.12 Scaling function control
Alternatively, this parameter can also be set during operation via acyclic parameter access to the
function control
PNU 65004
bit 3, see page 136.
Selection
Value Description
Default
disable
0
Scaling function switched off
X
enable
1
The scaling function with the parameters
Scaling:
Measuring step [nm]
and
Scaling: Total
Measuring Range is applied if Enable
is set in the
parameter
Encoder Class 4 functionality
.