Parameterization and Configuration
TR-Electronic GmbH 2018, All Rights Reserved
Printed in the Federal Republic of Germany
Page 138 of 167
TR - ELA - BA - DGB - 0027 - 03
11/12/2019
6.3.4.5 Scaling: Measuring step [nm] (PNU 65006)
The resolution of the measuring system is set in [nm] via this parameter, also see chapter 6.3.3.15 on
PNU
65006
Meaning
Resolution in nm
Data type
Unsigned32
Access
read/write
Activation
PNU 972
Save
PNU 971
Bits
Definition
0-31
0x0000 03E8 (1000):
Resolution = 1 µm per step
0x0000 07D0 (2000):
Resolution = 2 µm per step
0x0000 1388D5000 (5):
Resolution = 5 µm per step
0x0000 2710D10 (000):
Resolution = 10 µm per step
0x0000 C350 (50 000):
Resolution = 50 µm per step
0x0001 86A0 (100 000): Resolution = 100 µm per step
0x000F 4240 (1000 000): Resolution = 1 mm per step
6.3.4.6 Scaling: Total Measuring Range (PNU 65007)
The total number of steps over the whole measuring range of the measuring system is defined with
this parameter, also see chapter 6.3.3.15 on page 124.
PNU
65007
Meaning
Total resolution in steps
Data type
Unsigned32
Access
read/write
Activation
PNU 972
Save
PNU 971