Parameterization and Configuration
TR-Electronic GmbH 2018, All Rights Reserved
Printed in the Federal Republic of Germany
Page 124 of 167
TR - ELA - BA - DGB - 0027 - 03
11/12/2019
Function
Compatibility mode
enabled (0) = V3.1
Compatibility mode
disabled (1) = V4.2
Control by PLC
(
STW2_ENC
, bit 10)
Is ignored, the control word
G1_STW
and the set values are always valid.
Control requested (
ZSW2_ENC
, bit 9)
is not supported and is set to 0.
is supported
Parameter
Tolerated
sign-of-life errors
Is not supported. One sign-of-life
error is tolerated.
However, the number of tolerated
errors can be set via
PNU 925
.
is supported
Parameter
Alarm
channel control
is supported
not supported; profile-specific
diagnosis via the alarm channel
is always active.
Profile Version PNU 965
31 (V3.1)
42 (V4.2)
6.3.3.15 Scaling parameters
If the scaling parameters
Scaling: Total Measuring Range
and
Scaling: Measuring
step
are enabled (
Encoder Class 4 functionality
=
enable
and
Scaling function
control
=
enable
), the physical resolution of 1 µm of the measuring system can be changed. The
position value output is binary decoded and is calculated with a zero point correction and the
code
sequence
set.
Scaling: Total Measuring Range [steps] =
Measuring length [mm]
Scaling: Measuring step [mm]