5.2 Connection
The pin assignment depends on the device type and is therefore noted at each
measuring system on the nameplate as pin assignment number. At the delivery of the
measuring system one device specific pin assignment in printed form is enclosed.
5.3 Bus termination
If the measuring system is the last slave in the PROFIBUS segment, the bus is to be
terminated with bus termination resistors.
In case of device type A, see Figure 1, the bus termination resistors are already
installed inside the device. By the internal wiring it is defined that this device type may
be connected
only as last slave
into the bus.
Note on the nameplate
: “Termination Resistor ON”
Figure 1: Type A, note on the nameplate
: “Termination Resistor ON”