Parameterization and configuration
TR-Electronic GmbH 2011, All Rights Reserved
Printed in the Federal Republic of Germany
Page 100 of 131
TR - ECE - BA - DGB - 0089 - 04
02/03/2016
Overview of operating parameters
see note on page 92
Bit coded operating parameters
DDLM_Set_Prm
Byte
9
Bit
7
– 0
Data
2
7
– 2
0
x = default setting
Bit Definition
= 0
= 1
Page
0
Count direction
ascending position values
for clockwise rotation
X
ascending position
values counter-
clockwise rotation
1
Class 2 Functionality
no
yes
X
2
Commissioning diagnostics
switched off
X
switched on
3
Scaling function
switched off
switched on
X
Associated operating parameters for scaling
Description see page 114
DDLM_Set_Prm
unsigned16
Byte
10
11
12
13
Bit
31
– 24
23
– 16
15
– 8
7
– 0
Data
2
31
– 2
24
2
23
– 2
16
2
15
– 2
8
2
7
– 2
0
Default (dec.)
0
4096
unused
Steps per revolution
DDLM_Set_Prm
unsigned32
Byte
14
15
16
17
Bit
31
– 24
23
– 16
15
– 8
7
– 0
Data
2
31
– 2
24
2
23
– 2
16
2
15
– 2
8
2
7
– 2
0
Default (dec.)
16777216
Total measuring range