Printed in the Federal Republic of Germany
TR-Electronic GmbH 2011, All Rights Reserved
02/03/2016
TR - ECE - BA - DGB - 0089 - 04
Page 103 of 131
Operating parameter Teach-In function
Description see page 111
DDLM_Set_Prm
unsigned8
Byte
10
Bit
7
6
5
4
3
2
1
0
Data
2
7
2
6
2
5
2
4
2
3
2
2
2
1
2
0
Disabled no status
(Default)
0
0
0
0
0
0
0
0
Disabled with status
0
0
0
0
0
0
1
0
Enabled with status
0
0
0
0
0
0
1
1
Associated operating parameters for scaling with gearbox function
Description see page 116
DDLM_Set_Prm
unsigned32
Byte
11
12
13
14
Bit
31
– 24
23
– 16
15
– 8
7
– 0
Data
2
31
– 2
24
2
23
– 2
16
2
15
– 2
8
2
7
– 2
0
Default (dec.)
16777216
Total measuring range
DDLM_Set_Prm
unsigned32
Byte
15
16
17
18
Bit
31
– 24
23
– 16
15
– 8
7
– 0
Data
2
31
– 2
24
2
23
– 2
16
2
15
– 2
8
2
7
– 2
0
Default (dec.)
4096
Revolutions numerator
DDLM_Set_Prm
unsigned16
Byte
19
20
Bit
15
– 8
7
– 0
Data
2
15
– 2
8
2
7
– 2
0
Default (dec.)
1
Revolutions denominator